  • Name: TR-TC20H Microwave Digestion Tank
  • Model : TR-TC20H
  • Erp code: 9000000449
  • | Share

TR-TC20H.jpg

Technical specifications and requirements

1. Quantity: 1 set

2. Delivery: 30 working days after the contract is signed

3. Place of delivery: user site

4. Applications: Suitable for all types of pre-treatment samples in the laboratory of major and trace elements and organic pollutants analysis

5. Supply requirements:

  5.1 Instrument Type: Microwave Digestion System

  5.2 Quantity: One pair

  5.3 Configuration Requirements:

           5.3.1 one of the Microwave Digestion System host  

5.3.2  Full tank of infrared temperature control system 1 set
5.3.3  Full tank pressure control system 1 set
5.3.4  high pressure digestion tank 20 sets (including all internal and external tank, cap, rotor 20, and all other components )

6. Technical Indicators
6.1 Instrument work environment:

    6.1.1 Voltage: 220VAC ± 10%
 Temperature: 15-30 ℃
 Relative Humidity: 20% -80% RH

  6.2 Instrument general requirements: the ability to quickly deal with the same batch of samples 1-20

  6.3 Performance Indicators

    6.3.1 Microwave design and content production qualification ISO9001 certificate 8.3.1 professional manufacturer and to ensure no casualties accidents

    6.3.2 All stainless steel structure, with multi-layered anti-corrosion coating Teflon

    6.3.3 Professional microwave magnetron

        6.3.3.1 machine maximum microwave power of not less than 2000W, 2000W output power control program

        6.3.3.2 Microwave output: continuous non-pulsed microwave

    6.3.4 Temperature Control System

        6.3.4.1 Temperature controlling way: infrared temperature sensor automatically work independently, without any connection, no contact and pollution control temperature

        6.3.4.2 Temperature control range 0-300 ℃

    6.3.5 Pressure Control System

        6.3.5.1 Pressure control system, the control pressure tank

    6.3.6 High pressure reaction vessel module

        6.3.6.1 The maximum temperature ≥ 300 ℃, the maximum pressure ≥ 1500psi.

6.3.6.2 Inner tank material: TFM material, size: 70Ml.

6.3.6.3 The outer tank material: Aerospace composite fiber material plus PEEK outer tank

6.3.6.4 Inner tank weight ≤ 100g, on balance, said samples directly, without transfer steps

6.3.6.5 High pressure digestion tank maximum amount of 20 sample batch / lot

    7. After-sale service terms

        7.1 Installation and commissioning and warranty: all instruments free onsite installation and on-site operator training, the warranty period is from the instrument of acceptance after 12 months or 15 months delivery, whichever comes first. Instrument maintenance of life.

        7.2 Training: Free on-site training, the number is not limited. Including the basic principles of the instrument, the instrument operation and maintenance application of knowledge until the user can properly use and maintain the equipment. Long-term technical support, and free for all applications and the latest equipment literature relevant information, such as user Proceedings published. It offers free equipment manuals, training materials, application articles.

 

         7.3 Maintenance: The instrument was signed by both parties after the installation, enter the warranty period. After receiving an invitation user maintenance equipment within two hours to respond. Need to site maintenance, arrival time: within 24 hours (including the reply time), within the scope of the component parts, such as warranty charge (except wearing parts). Service during the warranty period does not charge service fees (including transportation, accommodation


Technical specifications and requirements:

1. Quantity: 1 set

2. Delivery: 30 working days after the contract is signed

3. Place of delivery: user site

4. Applications: Suitable for all types of pre-treatment samples in the laboratory of major and trace elements and organic pollutants analysis

5. Supply requirements:

  5.1 Instrument Type: Microwave Digestion System

  5.2 Quantity: One pair

  5.3 Configuration Requirements:

5.3.1 one of the Microwave Digestion System host  
5.3.2  Full tank of infrared temperature control system 1 set 
5.3.3  Full tank pressure control system 1 set 
5.3.4  high pressure digestion tank 20 sets (including all internal and external tank, cap, rotor 20, and all other components )

6. Technical Indicators 
6.1 Instrument work environment:

    6.1.1 Voltage: 220VAC ± 10% 
 Temperature: 15-30 ℃ 
 Relative Humidity: 20% -80% RH

  6.2 Instrument general requirements: the ability to quickly deal with the same batch of samples 1-20

  6.3 Performance Indicators

    6.3.1 Microwave design and content production qualification ISO9001 certificate 8.3.1 professional manufacturer and to ensure no casualties accidents

    6.3.2 All stainless steel structure, with multi-layered anti-corrosion coating Teflon

    6.3.3 Professional microwave magnetron

        6.3.3.1 machine maximum microwave power of not less than 2000W, 2000W output power control program

        6.3.3.2 Microwave output: continuous non-pulsed microwave

    6.3.4 Temperature Control System

        6.3.4.1 Temperature controlling way: infrared temperature sensor automatically work independently, without any connection, no contact and pollution control temperature

        6.3.4.2 Temperature control range 0-300 ℃

    6.3.5 Pressure Control System

        6.3.5.1 Pressure control system, the control pressure tank

    6.3.6 High pressure reaction vessel module

        6.3.6.1 The maximum temperature ≥ 300 ℃, the maximum pressure ≥ 1500psi.

6.3.6.2 Inner tank material: TFM material, size: 70Ml.

6.3.6.3 The outer tank material: Aerospace composite fiber material plus PEEK outer tank

6.3.6.4 Inner tank weight ≤ 100g, on balance, said samples directly, without transfer steps

6.3.6.5 High pressure digestion tank maximum amount of 20 sample batch / lot

    7. After-sale service terms

        7.1 Installation and commissioning and warranty: all instruments free onsite installation and on-site operator training, the warranty period is from the instrument of acceptance after 12 months or 15 months delivery, whichever comes first. Instrument maintenance of life.

        7.2 Training: Free on-site training, the number is not limited. Including the basic principles of the instrument, the instrument operation and maintenance application of knowledge until the user can properly use and maintain the equipment. Long-term technical support, and free for all applications and the latest equipment literature relevant information, such as user Proceedings published. It offers free equipment manuals, training materials, application articles.

       7.3 Maintenance: The instrument was signed by both parties after the installation, enter the warranty period. After receiving an invitation user maintenance equipment within two hours to respond. Need to site maintenance, arrival time: within 24 hours (including the reply time), within the scope of the component parts, such as warranty charge (except wearing parts). Service during the warranty period does not charge service fees (including transportation, accommodation



0