Main Technical Parameters:
1. Using PFA to paint the chamber, which is corrosion resistant and against high temperature, and can last for at least five years without corrosion
2. Liquid crystal display, temperature-programmed, accurate temperature of the digestion tank, automatic cut-off of the microwave by over-temperature and active defense of accidental over-temperature
3. Intelligent PID for auto-control to ensure the accuracy of sample digestion time and temperature
4. Multiple active and passive safety measures: intelligent security alarm, "deflated overpressure relief" and "explosion-proof membrane"
5. Overheat protection: When the box or external tank is overheated, the instrument will automatically trigger alarm and stop microwave radiation, it is with double-buffer explosion-proof door structure
6. Microwave power: 1000W; Frequency: 2450MHz
7. Using platinum resistance temperature control system for real-time display and temperature-control of the digestion tank, temperature-control range: 0-300 ℃, monitoring accuracy: 0.1 ℃ (with inspection certificate)
8. Equipped with high-precision and high-temperature melt pressure sensor or non-contact inductive frequency-modulation pressure monitor to display and control pressure in the reaction tank, Control range: 0.1-10MPa, Precision: 0.01MPa
9. At least six samples can be treated simultaneously (capacity ≥ 100m), and at least six sets of microwave digestion tank assembly are equipped
10. The internal tank is made of TFM with the capacity of over 100mL, and the external tank is made of PEEK, which is resistant to high temperature, high pressure and acid corrosion
11. Uniform chamber design ensures simultaneous treatment of all samples, using PFA to paint the chamber, with multiple high-temperature anti-corrosion coatings, preventing the chamber from acid and solvents corrosion.
12. Equipped with larger-power ventilation system in the chamber, thus all reactions can be done continuously under a ventilated, secure, and easy-for-observation condition
13. Configuration: microwave digestion host, PEEK digestion tank assembly outside the tank 6 sets, TFM digestion tank tank (capacity ≥ 100m) assembly 6 sets (including master a set), the temperature sensor 2 sets, manual certificate must be equipped with other accessories
Main Technical Parameters:
1. Using PFA to paint the chamber, which is corrosion resistant and against high temperature, and can last for at least five years without corrosion
2. Liquid crystal display, temperature-programmed, accurate temperature of the digestion tank, automatic cut-off of the microwave by over-temperature and active defense of accidental over-temperature
3. Intelligent PID for auto-control to ensure the accuracy of sample digestion time and temperature
4. Multiple active and passive safety measures: intelligent security alarm, "deflated overpressure relief" and "explosion-proof membrane"
5. Overheat protection: When the box or external tank is overheated, the instrument will automatically trigger alarm and stop microwave radiation, it is with double-buffer explosion-proof door structure
6. Microwave power: 1000W; Frequency: 2450MHz
7. Using platinum resistance temperature control system for real-time display and temperature-control of the digestion tank, temperature-control range: 0-300 ℃, monitoring accuracy: 0.1 ℃ (with inspection certificate)
8. Equipped with high-precision and high-temperature melt pressure sensor or non-contact inductive frequency-modulation pressure monitor to display and control pressure in the reaction tank, Control range: 0.1-10MPa, Precision: 0.01MPa
9. At least six samples can be treated simultaneously (capacity ≥ 100m), and at least six sets of microwave digestion tank assembly are equipped
10. The internal tank is made of TFM with the capacity of over 100mL, and the external tank is made of PEEK, which is resistant to high temperature, high pressure and acid corrosion
11. Uniform chamber design ensures simultaneous treatment of all samples, using PFA to paint the chamber, with multiple high-temperature anti-corrosion coatings, preventing the chamber from acid and solvents corrosion.
12. Equipped with larger-power ventilation system in the chamber, thus all reactions can be done continuously under a ventilated, secure, and easy-for-observation condition
13. Configuration: microwave digestion host, PEEK digestion tank assembly outside the tank 6 sets, TFM digestion tank tank (capacity ≥ 100m) assembly 6 sets (including master a set), the temperature sensor 2 sets, manual certificate must be equipped with other accessories