Instruction:

This pumps is single channel syringe pump which has infusion/withdrawal mode. The acceptable syringe specifications are from 10 µL to 140 mL. Suitable for high accuracy and small flow rate liquid transferring.


Specification:

- Max. Infusion Distance: 90 mm 
- Acceptable Sample Syringe: 5 µL - 60 mL 
- Linear Speed: 7.9 µm/min - 79.4 mm/min 
- Adjusting Resolution: 7.9 µL/min 
- Distance Resolution: 0.165 µm 
- Linear Force: > 90 N 
- Setting Mode: Membrane keypad and rotary coded switch 
- Control Accuracy: < +/- 0.5% in condition of 30% of the full stroke 
- Display: 128x64 graphic LCD 
- External Control Interface: Start/Stop control, fast forward control, fast reverse control 
- Communication Interface: RS485 
- Power Supply: AC 100 V - 240 V or DC12V 
- Power Consumption: < 10W 
- Operating Condition: Temperature 0 to 40°C; relative humidity < 80% 
- Controller Dimensions (Lx W x H) : 170 x 108 x 70 (mm) 
- Controller Weight: 0.8 Kg 
- Drive Unit Dimensions (L x W x H): 245 x 100x 95 (mm) 
- Drive Unit Weight: 1.3 Kg


Functions and features:

- User-defined syringe: Storing 4 inner diameters of user-defined syringe 
- Linear force output: > 90 N 
- Adopt membrane keypad, easy to operate 
- Memory function: Storing the running parameters automatically 
- Signal outputs: Start/Stop output, cw/ccw output (Open Collector) 
- Calibration: Acquire accurate volume through calibration 
- Fast forward & fast reverse: Infusion or withdrawal at the max. speed (158.8 mm/min)


Parameters:

Controller Type (Product Code)Drive Unit (Product Code)Syringe (ml)Syringe ID (mm)Flow Rate  (μl/min-ml/minTR-TC-3A (0503121)W0109-1B (0503021)14.720.139-1.3929.000.505-5.05513.101.07-10.71016.601.718-17.182019.002.251-22.513023.003.298-32.986029.145.295-52.95

 

  


Specification:

- Max. Infusion Distance: 90 mm 
- Acceptable Sample Syringe: 5 µL - 60 mL 
- Linear Speed: 7.9 µm/min - 79.4 mm/min 
- Adjusting Resolution: 7.9 µL/min 
- Distance Resolution: 0.165 µm 
- Linear Force: > 90 N 
- Setting Mode: Membrane keypad and rotary coded switch 
- Control Accuracy: < +/- 0.5% in condition of 30% of the full stroke 
- Display: 128x64 graphic LCD 
- External Control Interface: Start/Stop control, fast forward control, fast reverse control 
- Communication Interface: RS485 
- Power Supply: AC 100 V - 240 V or DC12V 
- Power Consumption: < 10W 
- Operating Condition: Temperature 0 to 40°C; relative humidity < 80% 
- Controller Dimensions (Lx W x H) : 170 x 108 x 70 (mm) 
- Controller Weight: 0.8 Kg 
- Drive Unit Dimensions (L x W x H): 245 x 100x 95 (mm) 
- Drive Unit Weight: 1.3 Kg

Functions and features:

- User-defined syringe: Storing 4 inner diameters of user-defined syringe 
- Linear force output: > 90 N 
- Adopt membrane keypad, easy to operate 
- Memory function: Storing the running parameters automatically 
- Signal outputs: Start/Stop output, cw/ccw output (Open Collector) 
- Calibration: Acquire accurate volume through calibration 
- Fast forward & fast reverse: Infusion or withdrawal at the max. speed (158.8 mm/min)

Parameters:

 

Controller Type (Product Code)Drive Unit (Product Code)Syringe (ml)Syringe ID (mm)Flow Rate  (μl/min-ml/minTR-TC-3A (0503121)W0109-1B (0503021)14.720.139-1.3929.000.505-5.05513.101.07-10.71016.601.718-17.182019.002.251-22.513023.003.298-32.986029.145.295-52.95

 