TR-TCSP02-1B Dual Channels Syringe Pump


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TCSP02-1B Dual Channels Syringe Pump
  • Model : TR-TCSP02-1B
  • Erp code: 9000000382
  • | Share

TR-TCSP02-1B.png

Instruction:

Labratorial syringe pumps are multi-channel syringe pump which have infusion/withdrawal mode. The acceptable syringe specification is from 10 µL to 140 mL. Suitable for high accuracy and small flow rate liquid transferring.


Specification:

Syringe Pump

TR-TCSP02-1B

Number of Channels

2

Display Setting

Display volume, flow rate, linear speed

Syringe Size

10µL – 140 mL

Power-off Memory

Storing the running parameters automatically

Dimensions (mm)

280×250×140

Weights (Kg)

4.3

Working Mode

Infusion / Withdraw

Linear Force

> 18Kg

Advance per Micro-step

1/16 Step (0.156µm)

Max. Step Rate

13867 (1/16 step) /sec

Min. Step Rate

16 (1/16) / 30 sec

Max. Linear Rate

130 mm/min

Min. Linear Rate

5µm/min

Accuracy

≤ 0.5% error in the condition of ≥ 30% of max. infusion distance

Setting Mode

Rotary coded switch and membrane keypad

Display

128x64 graphic LCD

Power Supply

AC100 -240V

Operation Condition

Temperature: 5 - 40, Relative humidity: <80%


Functions and features:

- Syringe Selection: The syringe can be selected in the manufacturer table which includes manufacturer, material and size or input the inner diameter of the syringe barrel directly 
- Easy to operate: Combining big screen LCD display with rotary coded switch and membrane keypad makes the operation simple and prompt. 
- Working Mode: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous 
- Memory Function: 1. The parameters are saved in EEPROM. The parameters don't need to be reset when power returns after an interruption. 2. In flow rate mode, the pump remains running or stop according to the setting parameters when power returns 
- Protection Function: The pump will stall and give an alarm when the drive structure of the pump is blocked 
- Communication Function: Realize computer control through RS485 communication interface 
- External Control Function: Input/output control 
- Calibration Function: Acquire accurate volume through calibration 
- Syringe Protection: Adjust syringe rest to prevent syringe from damaging


Parameters:

Type

Product Code

Syringe

Syringe ID (mm)

Flow Rate (μl/min-ml/min)

TR-TCSP02-1B

0503441

10μl

0.50

0.001-0.0255

25μl

0.80

0.0025-0.0653

50μl

1.10

0.0048-0.1235

100μl

1.60

0.0101-0.2614

250μl

2.30

0.0208-0.5401

500μl

3.25

0.0415-1.0784

1ml

4.72

0.0875-2.2747

2ml

9.00

0.3181-8.2702

5ml

13.10

0.6739-17.522

10ml

16.60

1.0821-28.135

20ml

19.00

1.4176-36.859

30ml

23.00

2.0774-54.012

60ml

29.14

3.3346-86.699

 


Parameters:

Type

Product Code

Syringe

Syringe ID (mm)

Flow Rate (μl/min-ml/min)

TR-TCSP02-1B

0503441

10μl

0.50

0.001-0.0255

25μl

0.80

0.0025-0.0653

50μl

1.10

0.0048-0.1235

100μl

1.60

0.0101-0.2614

250μl

2.30

0.0208-0.5401

500μl

3.25

0.0415-1.0784

1ml

4.72

0.0875-2.2747

2ml

9.00

0.3181-8.2702

5ml

13.10

0.6739-17.522

10ml

16.60

1.0821-28.135

20ml

19.00

1.4176-36.859

30ml

23.00

2.0774-54.012

60ml

29.14

3.3346-86.699

 



0