TR-TCSP01-1C Push & Pull Syringe Pump


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TCSP01-1C Push & Pull Syringe Pump
  • Model : TR-TCSP01-1C
  • Erp code: 9000000387
  • | Share

TR-TCSP01-1C.jpg

Instruction:

Labratorial syringe pump is a two-syringe push-pull syringe pump. The acceptable syringe specification is from 10μL to

 10mL. Suitable for high accuracy and small flow rate liquid continuously transferring.

 

Specification:

- Syringe size: 10μL-10mL 
- Linear force: 9 Kg 
- Advance per mircostep: 0.156 μm 1/16step 
- Infusion volume per microstep: 0.026μL (10mL syringe 1/16 step) 
- Max. step rate: 6933 1/16step /sec 
- Min. step rate: 16 1/16step /30sec 
- Max. linear rate: 65 mm/min 
- Min. linear rate: 5μm/min 
- Flow rates: 0.831 nL/min-10.84mL/min 
- Accuracy: ≤0.5% error in the condition of 
- Setting mode: Rotary coded switch and membrane keypad 
- Display: 128×64 graphic LCD 
- Power supply: AC100-240V 
- Operating condition: Temperature 5-40, relative humidity <80%. 
- Dimensions: 280×220×140(mm) 
- Weight: 3.6 kg


Functions and features:

- Syringe Selection: The syringe can be selected in the manufacturer table which includes manufacturer, material 

and size or input the inner diameter of the syringe barrel directly 
- Easy to operate: Combining big screen LCD display with rotary encoder switch and membrane keypad makes the 

operation simple and prompt. 
- Working Mode: Push-pull 
- Memory Function: 1. The parameters are saved in EEPROM. The parameters don't need to be reset when power

 returns after an interruption. 2. In flow rate mode, the pump remains running or stops according to the setting

 parameters when power returns after an interruption 

- Protection Function: The pump will stall and give an alarm when the drive structure of the pump is blocked 
- Communication Function: Realize computer control through RS485 communication interface 
- External Control Function: Input/output control 
- Calibration Function: Acquire accurate volume through calibration 
- Syringe Protection: Adjust syringe rest to prevent syringe from damaging 


Specification:

- Syringe size: 10μL-10mL 
- Linear force: 9 Kg 
- Advance per mircostep: 0.156 μm 1/16step 
- Infusion volume per microstep: 0.026μL (10mL syringe 1/16 step) 
- Max. step rate: 6933 1/16step /sec 
- Min. step rate: 16 1/16step /30sec 
- Max. linear rate: 65 mm/min 
- Min. linear rate: 5μm/min 
- Flow rates: 0.831 nL/min-10.84mL/min 
- Accuracy: ≤0.5% error in the condition of 
- Setting mode: Rotary coded switch and membrane keypad 
- Display: 128×64 graphic LCD 
- Power supply: AC100-240V 
- Operating condition: Temperature 5-40, relative humidity <80%. 
- Dimensions: 280×220×140(mm) 
- Weight: 3.6 kg

Functions and features:

- Syringe Selection: The syringe can be selected in the manufacturer table which includes manufacturer, material and size or input the inner diameter of the syringe barrel directly 
- Easy to operate: Combining big screen LCD display with rotary encoder switch and membrane keypad makes the operation simple and prompt. 
- Working Mode: Push-pull 
- Memory Function: 1. The parameters are saved in EEPROM. The parameters don't need to be reset when power returns after an interruption. 2. In flow rate mode, the pump remains running or stops according to the setting parameters when power returns after an interruption 
- Protection Function: The pump will stall and give an alarm when the drive structure of the pump is blocked 
- Communication Function: Realize computer control through RS485 communication interface 
- External Control Function: Input/output control 
- Calibration Function: Acquire accurate volume through calibration 
- Syringe Protection: Adjust syringe rest to prevent syringe from damaging 



0