TR-TCSP01-1BH High Pressure Syringe Pump


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TCSP01-1BH High Pressure Syringe Pump
  • Model : TR-TCSP01-1BH
  • Erp code: 9000000386
  • | Share

TR-TCSP01-1BH.png

Instruction:

Labratorial syringe pump is a single channel high pressure syringe pump. The acceptable syringes are 2.5 L-100mL stainless steel syringes. Because of the extra linear force this pump is suitable for transferring viscose fluids or delivering the fluid to reactors in chemical applications.


Specification:

- Syringe size:

2.5mL-100mL

- Linear force:

45kg

- Advance per micro-step:

0.156μL (100mL syringe 1/16 step)

- Infusion volume per micro-step:

0.149μL (100mL syringe 1/16 step)

- Max. step rate:

13867(1/16 step)/sec

- Min. step rate:

16 (1/16 step) /30 sec

- Max. linear rate:

130mm/min

- Min. linear rate:

5μm/min

- Flow rates:

0.09μL/min-124.36 ml/min

- Accuracy:

≤±0.5% error in the condition of ≥30% of max. infusion distance

- Setting mode:

Rotary coded switch and membrane keypad

- Display:

128×64 graphic LCD

- Power:

AC100-240V

- Operating condition:

Temperature 5-40

Relative humidity <80%

- Dimensions:

280×250×140 (mm)

- Weight:

6.3kg

 

Functions and features:

- Syringe Selection: The syringe can be selected in the manufacturer table which includes manufacturer, material and size or input the inner diameter of the syringe barrel directly 
- Easy to operate: Combining big screen LCD display with rotary encoder switch and membrane keypad makes the operation simple and prompt. 
- Working Mode: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous 
- Memory Function: 1. The parameters are saved in EEPROM. The parameters don't need to be reset when power returns after an interruption. 2. In flow rate mode, the pump remains running or stop according to the setting parameters when power returns after an interruption 
- Protection Function: The pump will stall and give an alarm when the drive structure of the pump is blocked 
- Communication Function: Realize computer control through RS485 communication interface 
- External Control Function: Input/output control 
- Calibration Function: Acquire accurate volume through calibration 
- Syringe Protection: Adjust syringe rest to prevent syringe from damaging.


Parameters:

Type

Product Code

Syringe

Syringe (mm)

Flow rate (μl/min-ml/min)

Outlet Pressure (Mpa)

TR-TCSP01-1BH

0503431

2.5

4.79

0.0901-2.3426

19.48

8

9.53

0.3567-9.2730

5.05

20

19.13

1.4371-37.3648

1.25

50

28.6

3.2121-83.5152

0.56

100

34.9

4.7831-124.361

0.37


Parameters:

 

Type

Product Code

Syringe

Syringe (mm)

Flow rate (μl/min-ml/min)

Outlet Pressure (Mpa)

TR-TCSP01-1BH

0503431

2.5

4.79

0.0901-2.3426

19.48

8

9.53

0.3567-9.2730

5.05

20

19.13

1.4371-37.3648

1.25

50

28.6

3.2121-83.5152

0.56

100

34.9

4.7831-124.361

0.37


0