  • Name: TR-TCSP01-1A Single Channel Syringe Pump
  • Model : TR-TCSP01-1A
  • Erp code: 9000000385
  • | Share

TR-TCSP01-1A.png


Instruction:

TR-TCSP01-1A & TR-TCSP01-2A  laboratorial syringe pumps are single channel syringe pump which only has infusion mode. The acceptable syringe specification is from 10 μL to 60 mL. Suitable for high accuracy and small flow rate liquid transferring.


Specification:

Syringe pump

TR-TCSP01-1A

TR-TCSP01-2A

No. of Syringes

1

1

Advance per Mircostep

1/16step: 0.156 μm

1/16step: 0.031 μm

Infusion Volumn per Microstep

0.13 μL (60 mL BD Syringe)

0.026 μL (60 mL BD Syringe)

Syringe Size

10 μL - 60 mL

10 μL - 60 mL

Max. Linear Rate

65 mm/min

13 mm/min

Min. Linear Rate

5μm/min

1μm/min

Flow Rate

0.831 nL/min -  54.155 ml/min

0.166 nL/min -  10.83 ml/min

Working Mode

Infusion

Linear Force

> 9 kgf

Max. Step Rate

6933  (1/16step)/ sec

Min. Step Rate

16  (1/16 step) /30 sec

Accuracy

≤ 0.5% error in the condition of > 30% of max. infusion distance

Setting Mode

Rotary coded switch and membrane keypad

Display

128 x 64 graphic LCD

Power

AC 100 - 240 V

Operating Condition

Temperature  5 °C - 40 °C       Relative humidity < 80 %

Dimensions

280 × 210 × 140 mm

280 × 210 × 140 mm

Weights

3.6 kg

3.6kg

 

Functions and features:

- Syringe Selection: The syringe can be selected in the manufacturer table which includes manufacturer, material and size or input the inner diameter of the syringe barrel directly 
- Easy to operate: Combining big screen LCD display with rotary coded switch and membrane keypad makes the operation simple and prompt. 
- Working Mode: Infusion 
- Memory Function: 
1. The parameters are saved in EEPROM. The parameters don't need to be reset when power returns after an interruption 
2. In flow rate mode, the pump remains running or stop according to the setting parameters when power returns after an interruption 
- Protection Function: The pump will stall and give an alarm when the drive structure of the pump is blocked 
- Communication Function: Realize computer control through RS485 communication interface 
- External Control Function: Input/output control 
- Calibration Function: Acquire accurate volume through calibration 
- Syringe Protection: Adjust syringe rest to prevent syringe from damaging


Parameters:

Type

Product Code

Syringe

Syringe ID (mm)

Flow Rate (μl/min-ml/min)

TR-TCSP01-1A

0503401

10μl

0.50

0.001-0.0128

25μl

0.80

0.0025-0.0327

50μl

1.10

0.0048-0.0618

100μl

1.60

0.0101-0.1307

250μl

2.30

0.0208-0.2701

500μl

3.25

0.0415-0.5392

1ml

4.72

0.0875-1.1373

2ml

9.00

0.3181-4.1351

5ml

13.10

0.6739-8.7608

10ml

16.60

1.0821-14.068

20ml

19.00

1.4176-18.429

30ml

23.00

2.0774-27.006

60ml

29.14

3.3346-43.349

 


Type

Product Code

Syringe

Syringe ID (mm)

Flow Rate (μl/min-ml/min)

TR-TCSP01-1A

0503401

10μl

0.50

0.001-0.0128

25μl

0.80

0.0025-0.0327

50μl

1.10

0.0048-0.0618

100μl

1.60

0.0101-0.1307

250μl

2.30

0.0208-0.2701

500μl

3.25

0.0415-0.5392

1ml

4.72

0.0875-1.1373

2ml

9.00

0.3181-4.1351

5ml

13.10

0.6739-8.7608

10ml

16.60

1.0821-14.068

20ml

19.00

1.4176-18.429

30ml

23.00

2.0774-27.006

60ml

29.14

3.3346-43.349



0