TR-TC3500 X fluorescence silicon aluminum analyzer


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TC3500 X fluorescence silicon aluminum analyzer
  • Model : TR-TC3500
  • Erp code: 2000000099
  • | Share

TR-KL3500.jpg

Main Usage:

TR-TC3500 X fluorescence silicon aluminum analyzer  adopts  X ray stimulating sample, detects produced quadratic character X ray, that is gaining silicon aluminum qualitative and quantitative analysis result. The product is widely applied in industries, such as metallurgy, mining, building materials, etc. It is used in cement factory, which mainly measure the percentage content of SiO2、Al2O3  in the  materials, such as raw material, clinker, limestone, clay, etc. Because of its fast analysis speed, ( 1 minute), so it could monitor the change condition of SiO2, Al2O3  in the production process in real time, so as to adjust the ratio of raw material in time, laying the solid foundation for producing high qualified rate of clinker. It is used in magnesium metal industry, fastest one minute could make quick analysis of SiO2, Al2O3 in deoxidizer , such as ferrosilicon. 


Main feature: 

1) Micro computer integrated as a whole, compact structure, beautiful appearance

2) Large screen LCD display, entirely in English menu prompt operation, convenient to use.

3) Short analysis time, percentage content of SiO2, Al2O3 given in 1 minute.

4) Don’t destroy samples when instrument detects, sample can be used  repeatedly .

5) Without any chemical reagent, no "three wastes" emissions, don’t contain radioactive source, low-power, comply with the requirement of environmental protection and energy saving.

6) Large data storage capacity, content result, instrument self-checking data could be queried, avoid printing supplier.

7) Instrument execute GB/T19140 《the general principles of cement X ray fluorescence analysis》


Technical indicator:

1) Analysis range: SiO2、Al2O3 0.01%~100%

2) Analysis precision : Standard deviation SSiO2≤0.10%、SAl2O3≤0.08%

3) Analysis width: SiO2(Al2O3) max—SiO2(Al2O3)min≤15%, for example 

In the raw material SiO2:10%~25%, selected according to calibration working curve.

4) Analysis time: n* 60S( n is 1-5 natural number)

5) Using condition: power supply AC200V-240V;environment temperature 0-40℃;Relative humidity<85%(30℃)

6) Overall power consumption: <30W

7) Overall dimension: 468*368*136mm

8) Total weight: 13.8kg


 Technical indicator

1) Analysis range: SiO2、Al2O3 0.01%~100%

2) Analysis precision : Standard deviation SSiO2≤0.10%、SAl2O3≤0.08%

3) Analysis width: SiO2(Al2O3) max—SiO2(Al2O3)min≤15%, for example 

In the raw material SiO2:10%~25%, selected according to calibration working curve.

4) Analysis time: n* 60S( n is 1-5 natural number)

5) Using condition: power supply AC200V-240V;environment temperature 0-40℃;Relative humidity<85%(30℃)

6) Overall power consumption: <30W

7) Overall dimension: 468*368*136mm

8) Total weight: 13.8kg


0