TR-TC-510E Solidifying Point&Cold Filter Plugging Point Tester


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TC-510E Solidifying Point&Cold Filter Plugging Point Tester
  • Model : TR-TC-510E
  • Erp code: 8000000040
  • | Share

Summary:
    The instrument is designed and made as per standards GB/T510 Standard Test Method for Solidifying Point of Petroleum Oils and SH/T0248 Diesel and domestic heating fuels- Determination of cold filter plugging point. t is suitable to determine solidifying point and cold filter plugging point of petroleum products.

 

Main technical features:
1. The material of bench is stainless steel. It is composed of chamber I and chamber II. There are two cooling baths in each chamber. The baths are the same in temperature.
2. It is no need to use cooling liquid in the chambers. The cooling rate is fast and efficiency is high. Temperature controller I and controller II control the temperature of chamber I and chamber II separately. The mim. temperature in chamber II can reach -70℃.The control precision is ±1℃.
3. The instrument adopts bench structure. The design is simple and easy to use. The filter for cold filter plugging point is provided. Operator can do both solidifying point test and cold filter plugging point test after buying this equipment.

 

Main technical specifications:
1. Power supply: AC 220 V±10%, 50 Hz;
2. Temperature control of chamber: 
    (1) Chamber I: Ambient to -51 ℃, ±1 ℃, temperatures of two cooling baths are the same.
    (2) Chamber II: Ambient to -70 ℃, ±1 ℃, temperatures of two cooling baths are the same.
3. Refrigeration system: New type refrigeration compressor
4. Ambient temperature: ≤30 ℃
5. Relative humidity: ≤85%
6. Maximum power consumption: 1500 W
7. Dimension: 800mm×580mm×400mm

SYD-510E.jpg

Main technical specifications
1. Power supply: AC 220 V±10%, 50 Hz;
2. Temperature control of chamber: 
    (1) Chamber I: Ambient to -51 ℃, ±1 ℃, temperatures of two cooling baths are the same.
    (2) Chamber II: Ambient to -70 ℃, ±1 ℃, temperatures of two cooling baths are the same.
3. Refrigeration system: New type refrigeration compressor
4. Ambient temperature: ≤30 ℃
5. Relative humidity: ≤85%
6. Maximum power consumption: 1500 W
7. Dimension: 800mm×580mm×400mm



No.

Item

Unit

Qty

Remarks

1

Thermometer(-80~60℃)scale division 1℃

Piece

1

GB / T 514 ID: GB-31

2

Cold filter plugging point test tube

Piece

4


3

Cold filter plugging point test tube plugs

A

2


4

Cold filter plugging point test tube positioning ring (Ф35 × 3 ○-ring)

A

2


5

Test tube for solidifying point

Set

2


6

Test tube stopper for solidifying point

A

2


7

Fixing ring for test tube of solidifying point(Ф50 × 7 ○-ring)

A

2


8

Fixed mount

A

1


9

Felt pad

Piece

2


10

Stopping ring for thermometer(1#)

Piece

2


11

Bath cover

A

4


12

○ typering (Ф9 × 1.5)

Piece

2


13

○ typering (Ф18× 2)

Piece

2


14

LC-1 cold filter plugging point suction filter

Set

1

Including complete accessories and instructions

15

15A fuse(Ф5×20)

Piece

2


16

Power line (250V 10A)

Piece

1


 


0