TR-TC-510D Pour Point&Cloud Point Tester


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TC-510D Pour Point&Cloud Point Tester
  • Model : TR-TC-510D
  • Erp code: 8000000038
  • | Share

Summary:
    The instrument is designed and made as per GB/T3535 Standard Test Method for Pour Point of Petroleum Oils and GB/T6986 Test Method for Cloud Point of Petroleum Oils in the National Standard of People’s Republic of China. It is suitable to determine pour point and cloud point of petroleum oils.
 
Main technical features:
1. The working table is stainless steel material. It has two chambers (chamber I and chamber II) .Each chamber equipped two cooling baths. The temperatures of these two baths are the same. All cooling baths can determine pour point and cloud point.
2. It is no need to use coolant in the chamber. The cooling speed is fast and cooling efficiency is high. The temperature controller I controls the temperature of chamber I and temperature controller II controls the temperature of chamber II. The minimum temperature of chamber II can reach -70℃ and temperature control precision is ±1℃.
3. The instrument adopts bench structure, concise design and easy to use. 
 
Main technical specifications:
1. Power supply: AC 220 V±10%, 50 Hz;
2. Temperature control of cooling chamber: 
    (1) Chamber I: Ambient to -51 ℃, ±1 ℃, temperatures of two cooling baths the same.
    (2) Chamber II: Ambient to -70 ℃, ±1 ℃, temperatures of two cooling baths the same.
3. Refrigeration system: New type refrigeration compressor
4. Ambient temperature: ≤30 ℃
5. Relative humidity: ≤85%
6. Maximum power consumption: 1500 W
7. Dimension: 800mm×580mm×400mm


SYD-510D.jpg

Main technical specifications
1. Power supply: AC 220 V±10%, 50 Hz;
2. Temperature control of cooling chamber: 
    (1) Chamber I: Ambient to -51 ℃, ±1 ℃, temperatures of two cooling baths the same.
    (2) Chamber II: Ambient to -70 ℃, ±1 ℃, temperatures of two cooling baths the same.
3. Refrigeration system: New type refrigeration compressor
4. Ambient temperature: ≤30 ℃
5. Relative humidity: ≤85%
6. Maximum power consumption: 1500 W
7. Dimension: 800mm×580mm×400mm



No.

Item

Unit

Qty

Remarks

1

Thermometer(-38~50℃)scale division 1℃

Piece

1

GB / T 514 ID: GB-37

2

Thermometer(-80~20℃)scale division 1℃

Piece

1

GB / T 514 ID: GB-36

3

Pour point tube plugs

Piece

4


4

Pour point tubes

Piece

4


5

Bath cover

Piece

4


6

Washers (Ф35 × 3.1 ○-ring)

Piece

4

Pour point tube positioning ring

7

Round dish

Piece

4

Felt gasket

8

15A fuse(Ф5×20)

Piece

2


9

Fixed mount

Piece

1


10

Stop collar for thermometer(1#)

Piece

2



0