Specifications:


Model:  TR-TC-SC810                                 

Acquisition 

system:  

 

imported digital high 

definition 

black/white CCD                                             
 

Effective

 resolution 

(pixels m) :

 
1360*1024    

Pixel Size 

(um V*H): 

 
4.65*4.65   
SNR:  
70db
Pixel Density:  
12 bit      
USB2.0 Lens:    
imported 6x motorized zoom F1.0, 

2/3 inch high caliber penetrating 

lens                

 
Darkroom:     

mold production, enclosed camera,

 built-in acquisition system,

 dustproofand shockproof, UV Safty                                                                                  

 
Filter:  
Standard 590 screw-type filter with 
coating  
(contact for special requirement)           

2Operation interface: with a panel

 or computer you can make full 

automatic control of zoom, focus, 

diaphragm, UV Trans and Reflect
lamps.                                                     
Display:    
Computer                                                               
 
UV Trans:   

Standard 21*26cm with 312nm 

(254/365nm)            

White Trans:       
Optional 20x28cm white light plate 
UV Reflect:       

Optional UV Reflect light source;

 used for paper chromatography and 

other Electrophoresis carrier which 

are opacity, but need a UV burst                                                                        

 
White Reflect:    
Standard LED white light                                     
 

Fixed time 

functions:  

 

Automatic switching off UV light 

source in 5 minutes (we can change

 it before product will leave the

 factory)             

 
Software:    

Genescope fully control-analysis

 software with Chinese interface, 

Win2000/XP, image capture, edit, 

analysis and database.                     

 
Power source:             
110/220V     
Dimension(mm):            
430*410*560          
Weight:   
22kg 
Certification:   
CE        


Main features:

Main features
 
More models are available. 

CE certification, more reliable.

Delicate computer, easy-moving, system noise is low. 

Darkroom with mold production, enclosed camera, built-in acquisition system,

 dustproof.

Detection sensitivity:20pg of double-stranded DNA.

Large area of UV transmission station, the biggest sample can be 21x26cm.

Wavelength of UV Trans and Reflect:standard 312nm,254/365nm are available.

The most safety UV glue cutting device. 

Equipment introduction:

Equipment introduction
 
Light, handy and quite Gel Documentation System.

TR-TC-SC810 Gel Documentation System
 uses 14 megapixels professional high definition black/white CCD with
 sensitivity of gel documentation in low-light level.                              

The system has UV automatic protection function, 
UV lamp automatically switches off when you are handling samples or 
it can enter glue cutting state and work with special protecting glue

 cutting device for worker`s safety.

The top of the system can be easily open for changing filters and different

 fluorescent stains. 
For standard 590nm filter you can use EB and GelRed stains, if you want to

 use other, 

please contact us for changing hardware.


Specifications


Model:  TR-TC-SC810                                 
Acquisition system:   
imported digital high definition 
black/white CCD                                             
 
Effective resolution (pixels m) : 
1360*1024    
Pixel Size (um V*H):  
4.65*4.65   
SNR:  
70db
Pixel Density:  
12 bit      
USB2.0 Lens:    
imported 6x motorized zoom F1.0, 
2/3 inch high caliber penetrating lens                
 
Darkroom:     
mold production, enclosed camera, built-in acquisition system, dustproof and shockproof, UV Safty                                                                                  
 
Filter:  
Standard 590 screw-type filter with 
coating  
(contact for special requirement)           
2Operation interface: with a panel or computer you can make full automatic control of zoom, focus, 
diaphragm, UV Trans and Reflect
lamps.                                                     
Display:    
Computer                                                               
 
UV Trans:   
Standard 21*26cm with 312nm (254/365nm)            
White Trans:       
Optional 20x28cm white light plate 
UV Reflect:       
Optional UV Reflect light source; used for paper chromatography and other Electrophoresis carrier which are 
opacity, but need a UV burst                                                                        
 
White Reflect:    
Standard LED white light                                     
 
Fixed time functions:   
Automatic switching off UV light source in 5 minutes (we can change it before product will leave the factory)             
 
Software:    
Genescope fully control-analysis software with Chinese interface, Win2000/XP, image capture, edit, analysis 
and database.                     
 
Power source:             
110/220V     
Dimension(mm):            
430*410*560          
Weight:   
22kg 
Certification:   
CE        