TR-TC-SC850 Gel Documentation System


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TC-SC850 Gel Documentation System
  • Model : TR-TC-SC850
  • Erp code: 9000000235
  • | Share


TR-TC-SC850.jpg


Specifications:

Model:      FluorShot EVO TR-TC-SC805
Acquisition system:  Professional high definition black/white CCD        
Effective resolution(pixelsm) : 1,280x 1,024  
Pixel Size (um V*H): 4.65*4.65       
SNR:   60db      
Pixel Density: 10 bit         
Port: USB 2.0   
Lens:Imported 6x motorized zoom F1.0, 2/3 inch high caliber penetrating lens             
 
Darkroom:     Mold production, enclosed camera, built-in acquisition system, dustproof and shockproof, UV Safty                                                                                
 
Filter:    Standard 590 screw-type filter with coating  (contact for special requirement)        
 
Operation interface:   With a panel or computer you can make full automatic control of zoom, focus, diaphragm, UV Trans and Reflect
 lamps.   
Display: Computer       
UV Trans: Standard 21*26cm with 312nm (254/365nm) 
White Trans: Optional 20x28cm white light plate 
UV Reflect:  Optional UV Reflect light source; used for paper
chromatography and other Electrophoresis carrier which are opacity, but need a UV burst                                
 
White Reflect:  Standard LED white light                                    
 
Fixed time functions:Automatic switching off UV light source in 5 minutes
(we can change it before product will leave the factory)
Software: Genescope fully control-analysis software with Chinese interface, Win2000/XP, image capture, edit, analysis and database.  
 
Power source:    110/220V           
Dimension(mm): 430*410*560  
Weight:      22kg          
Certification:CE   


Main features:

CE certification, export sales
The results are clean, price is cheap, quality-price ratio is high; 
Detection sensitivity:20pg of double-stranded DNA; 
Large area of UV transmission station, the biggest sample can be 21x26cm;
Standard LED white light, operation life is long 
Darkroom with mold production, enclosed camera, built-in acquisition system, dustproof;
With a panel or computer you can make full automatic control of zoom, focus, diaphragm, 
UV Trans and Reflect lamps. 
UV lamp automatically switches off when you are handling samples. 
It uses with the most safety UV glue cutting device, it can enter to the glue cutting state, 
and it`s easy to recover special proceed of nucleic acid.
Standard 590 screw-type filter with coating which is easy to change.
Optional Trans UV/white light, used for albumin glue and other Electrophoresis carrier which are opacity, 
but need a UV.
System size: 30*44*32 cm (length*height*depth) 
All software`s functions are stable, and you always can upgrade it for free. 


Equipment introduction:

With Biotop Gel Documentation Systems you can handle various images of nucleic acid and 
protein electrophoresis.With a panel or computer you can make basic operations as image capture, edit, 
analysis and printing. 
FluorShot EVO 805 has stable functions and high quality-price ratio.
The system has UV automatic protection function, UV lamp automatically switches off when you are handling 
samples or it can enter to the glue cutting state and work with special protecting glue cutting device for worker`s safety.

The top of the system can be easily open for changing filters and different fluorescent stains. 
For standard 590nm filter you can use EB and GelRed stains, if you want to use other, 
please contact us for changing hardware.

Model:    TR-TC-SC850                                                         
Acquisition system:    Professional high definition black/white CCD                                               
 
Effective resolution (pixels m) :2,592x 1,944   
Pixel Size (um V*H):      5.2*5.2 
SNR:  70db  
Pixel Density:     12 bit      
Port:  USB 2.0
Lens: Imported 6x motorized zoom F1.0, 2/3 inch high caliber penetrating lens             
 
Darkroom:Mold production, enclosed camera, built-in acquisition system, dustproof and shockproof, UV
Safty    
Filter:    Standard 590 screw-type filter with coating  (contact for special requirement)        
 
Operation interface:    With a panel or computer you can make full
automatic control of zoom, focus, diaphragm, UV Trans and Reflect lamps. 
Display:    Computer        
UV Trans:        Standard 21*26cm with 312nm (254/365nm)  
Optional 20x28cm white light plate  
UV Reflect:   Optional UV Reflect light source; used for paper chromatography and other Electrophoresis carrier which 
are opacity, but need a UV burst                                
 
White Reflect:      Standard LED white light         
Fixed time functions:     
Automatic switching off UV light source in 5 minutes (we can change it before product will leave the factory)  
 
Software:    Genescope fully control-analysis software with Chinese interface, Win2000/XP, image capture, edit, analysis and 
database.  
Power source:        110/220V    
Dimension(mm):     430*410*560 
Weight:  22kg  
Certification: CE   


0