TR-TCX-T Anaerobic incubator


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TCX-T Anaerobic incubator
  • Model : TR-TCX-T
  • Erp code: 9000000215
  • | Share

TR-TCX-T.png

Application Range:

This type of product is in the bacterial culture under anaerobic conditions and operating. This device can nurture the growth of anaerobic organisms most difficult. Anaerobic organisms can avoid the risk of death that anaerobic organisms are exposed to oxygen.


Structural Characteristics:

The equipment is composed of the incubation chamber, operating chamber, sampling chamber, pneumatics system, bottle rack, melting wax sterilize and etc.


Main Features:

1. Microcomputer intelligent temperature controlling and overheating protection system.

2. UV disinfection light to avoid pollution.

3. Gas flow adjusted by pneumatics system.

4. Stainless steel operation room chamber. Thick, transparent and impact resistant glass window. Operations should be with gloves.

5. Special vaccination sticks sterilizer, cuvette rack and oxygen removing catalyst converter inside.


Features:

TR-TCX-T  anaerobic culture case for our company the latest development of a new generation with large screen panel (touch screen type microcomputer control, can accurately and visually control incubator temperature and gas. It’s safe, reliable, concise intuitive and easy-to-use.

This system adopts the Siemens PLC as the core controller, complementary with high precision temperature sensors, oxygen sensor, temperature control module and analog module, high control precision, good stability, high safety. Humanized man-machine interface,facilitate operation personnel to process data in real time monitoring.

Imported oxygen sensors, can observe the indoor oxygen concentration.


Technical Parameter Table:

 

Model

TR-TCX- T

Time for creating anaerobic state in sample chamber

<5min

Time for creating anaerobic state in operation chamber

<1hour

Time for maintaining anaerobic circumstances

in the case of the operating room to stop additional trace gas mixture,>12 hours

Range of temperature-control in incubation chamber

RT+3℃~60℃

Temperature fluctuation in incubation chamber

±0.3℃

Temperature balance in incubation chamber

±1℃

Power Rate

220V,50HZ/600W

Net/Gross weight(kg)

240/320

Internal Dimension of Incubation Chamber(cm)

30×19×29

Dimension of Operation Chamber(cm)

80×65×65

Overall Dimension(cm)

126×73×138

Package Size(cm)

139×92×156

 

 

 

 


Technical Parameter Table:

 

Model

TR-TCX-I/II/ T

Time for creating anaerobic state in sample chamber

<5min

Time for creating anaerobic state in operation chamber

<1hour

Time for maintaining anaerobic circumstances

in the case of the operating room to stop additional trace gas mixture, > 12 hours

Range of temperature-control in incubation chamber

RT+3°C~60°C

Temperature fluctuation in incubation chamber

±0.3°C

Temperature balance in incubation chamber

±1°C

Power Rate

220V,50HZ/600W

Net/Gross weight (kg)

240/320

Internal Dimension of Incubation Chamber (cm)

30×19×29

Dimension of Operation Chamber (cm)

80×65×65

Overall Dimension (cm)

126×73×138

Package Size (cm)

139×92×156


0