TR-TCS-7002 ATOMIC ABSORPTION SPECTROPHOTOMETER


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TCS-7002 ATOMIC ABSORPTION SPECTROPHOTOMETER
  • Model : TR-TCS-7002
  • Erp code: 9000000182
  • | Share

TR-TC-7002 .jpg

Introduction:

  1. Optical suspension system. Superb by design, the instrument stands up to the test of shaking environment and tough temperature condition.

  2. Uniquely designed, one system can be configured to have both flame and graphite furnace installed. The switching between these 2 takes about a few seconds. AA-7000 is the most compact AAS system in the world.

  3. Titanium atomized system. It takes advantage of the aero-space technology, use titanium
    atomized system and burner. It is more resist to erosion, oxidation, and high temperature. The design helps increasing the lifetime of the instrument.

  4. 1800 lines/mm diffraction grating, to achieve higher resolution and higher energy.

  5. Deuterium-lamp and background deduction technology, to make the result adjusted more accurately.

  6. Alarming system, in order to guarantee the safety of lamps, graphite furnace, and flame, special design was considered at the beginning. so to make an instrument more reliable and safe to use.

  7. Option to our HG-01 hydride generator, to help your analysis on these elements as AS, Pb, Se, Hg etc..

  8. Graphite furnace auto sampler, auto sampler the process of preparation of standard solvents and sample. Repeatability is better than 98%.


Technical Parameters:

  1. Wavelength Range:  190nm~900nm

  2. Wavelength Accuracy:  Full Wavelength ≤±0.2nm

  3. Spectrum Bandwidth:   0.1, 0.2, 0.4, 2.0nm

  4. Resolution:  Mn 279.5nm, 279.9nm 

  5. Energy at the wave bottom≤3%

  6. Detecting methods:  Flame
    Lamp:  Hollow Cathode lamp
    Adjustable current:0~20mA
    Deuterium lamp
    Adjustable current:0~200mA

  7. Baseline stability:   ≤±0.004Abs/30min

  8. Abs Range:   0~4Abs

  9. Benchmark Elements:
    Flame: Cu 5mg/l produces 0.75/Abs, 
    Sensitivity: ≤±0.04mg/l,
    RSD%: ≤3%
    Graphite Furnace: Cd ≤0.5×10-12g
    RSD%≤ 3%

  10. Power Voltage: 110V/220V, 50Hz AC, 200W

  11. Size: 800×540×480(mm)

  12. Net Weight: 125kg (including flame furnace)




Technical Parameters

  1. Wavelength Range:  190nm~900nm

  2. Wavelength Accuracy:  Full Wavelength ≤±0.2nm

  3. Spectrum Bandwidth:   0.1, 0.2, 0.4, 2.0nm

  4. Resolution:  Mn 279.5nm, 279.9nm 

  5. Energy at the wave bottom≤3%

  6. Detecting methods:  Flame
    Lamp:  Hollow Cathode lamp
    Adjustable current:0~20mA
    Deuterium lamp
    Adjustable current:0~200mA

  7. Baseline stability:   ≤±0.004Abs/30min

  8. Abs Range:   0~4Abs

  9. Benchmark Elements:
    Flame: Cu 5mg/l produces 0.75/Abs, 
    Sensitivity: ≤±0.04mg/l,
    RSD%: ≤3%
    Graphite Furnace: Cd ≤0.5×10-12g
    RSD%≤ 3%

  10. Power Voltage: 110V/220V, 50Hz AC, 200W

  11. Size: 800×540×480(mm)

  12. Net Weight: 125kg (including flame furnace)


0