Low temperature kinematic viscometer (semi-automatic type)


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: Low temperature kinematic viscometer (semi-automatic type)
  • Model : TR-TC-2001A
  • Erp code: 8000000025
  • | Share

Description:
TR-TC-2001A Low temperature kinematic viscometer (semi-automatic type) ASTM D445 standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity).  This test method specifies a procedure for the determination of the kinematic viscosity, ν, of liquid petroleum products, both transparent and opaque, by measuring the time for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer. The dynamic viscosity, η, can be obtained by multiplying the kinematic viscosity, ν, by the density, ρ, of the liquid。The range of kinematic viscosities covered by this test method is from 0.2 to 300 000 mm2/s at all temperatures. The precision has only been determined for those materials, kinematic viscosity ranges and temperatures as shown in the footnotes to the precision section.

 

Features:
1. The apparatus consists of temperature controlling device, heating device, glass bath, bath lighting, and dedicated cooling source, stirring device and viscometer clips.
2. The apparatus adopts digital display temperature controller, temperature control high precision, easy to adjust.
3. The apparatus adopts heating tube to heat, heat fast and can make the bath evenly warmed.
4. Using Dewar cold bath, transparency, good insulation properties.
5. H lighting equipment facilitates observation the sample of cold bath.
6. Imported compressor, refrigeration compressor technology, cooling capacity, cooling speed.
7. Using motor stirrer to make cold bath temperature constant.
8. Cold bath cover with two holes comprises a new viscometer clip, easy to operate, while oil sample test can be done in parallel to improve efficiency.
9. Reasonable structure with beautiful shape and easy to operate.

 

Specification:

Technical parameters:

Rated voltage

AC220V±10% 50Hz or110V ±10% 60Hz

Power

1200W

Heating power

800W

Cold bath volume

8L

Temperature control

Digital display temperature control

Temperature range

20~60℃

Temperature accuracy

±0.1℃

Temperature sensor

Pt100(Platinum resistor)

Slot holes

Single

Mixing method

Stirring motor,1200r/min

Cooling time

≤120min

Ambient requirements

Temperature≤30°C,Humidity≤80%


PT-HK-2001A.jpg

Technical parameters

 

Rated voltage

AC220V±10% 50Hz or110V ±10% 60Hz

Power

1200W

Heating power

800W

Cold bath volume

8L

Temperature control

Digital display temperature control

Temperature range

20~60℃

Temperature accuracy

±0.1℃

Temperature sensor

Pt100(Platinum resistor)

Slot holes

Single

Mixing method

Stirring motor,1200r/min

Cooling time

≤120min

Ambient requirements

Temperature≤30°C,Humidity≤80%