  • Name: TR-TCDX400
  • Model : TR-TCDX400
  • Erp code: 9000000145
  • | Share

TR-TCDX400.jpg

Instrument introduction:

TR-TCDX400 Compact Multi-channel X-Ray Fluorescence Spectrometer features for 10 fixed light diffraction channels, with 10 arbitrary elements defined by the users from Na to U being analyzed simultaneously. The standard ten elements configuration is Na, Mg, Al, Si, S, Cl, K, Ca, Fe, P or Ti(optional). The instrument is an ideal quality control choice for large and medium-sized enterprises. 
Higher X-ray power, higher measurement precision, more stable measurement data, higher excitation efficiency, lower limit of detection


Performance characteristics:

a. reach adequate measurement accuracy with smaller power and equivalent measurement time; 
b. prolonged service life. 
c. fewer failures in high voltage supply, 
d. lower maintenance costs of the overall instrument,
e. no wearing problem of goniometer as fixed channels adopted.
f. Rapid and non-destructive analysis of powder sample and lump sample
g. Fast analyzer of compacted powder, fused beads and lump material
h. Multi-channel digital MCA has greatly improved the measurement efficiency, which benefits not only the instrument debugging and failure diagnosis but also enhances the measurement accuracy and stability.


Technical specifications:

High voltage supply: 400W (50KV8mA)
X-ray tube: 400W thin Be end window X-ray tube made by Varian company, Rh anode (Pd anode optional) 
Measurable elements: 10 arbitrary elements from Na to U. 
Detector: gas flow proportional detector + sealed proportional detector; 10 paths 1024 channels independent pulse height analyzer
Vacuum system: independent pumping station for easy maintenance with highest vacuum lower than 5 Pa 
Gas flow system: high-accuracy gas density stabilizer with pressure stability up to ±0.003 KPa. 
MCA: MCA measures the peak of every element in real time, which is not only good for instrument debugging and failure diagnosis but also enhance its analysis accuracy and stability. 
AC 220V power supply: 1KVA AC purified stabilized voltage power supply 
Analysis accuracy: oη-1 (24 hours,percentage content) ≤0.05 %.
Temperature control precision in constant temperature chamber: setting value士0.1°C.

Standard configurations

400W high-voltage power
400W Be end window X-ray tube 
Gas flow proportional detector + sealed proportional detector
10 paths of 1024-channel independent pulse height analyzer
Independent vacuum pumping structure
High sophisticated flow density stabilizer 
Multi-channel MCA real-time detection system
1KVA AC purified stabilized current

Application fields

Building materials (cement, glass, ceramic, etc) 
Steel 
Non-ferrous metals 
Minerals, 
Geography 
Chemical engineering 
Petroleum 
Quality inspection 
Commodity inspection


Technical specifications

High voltage supply: 400W (50KV8mA)
X-ray tube: 400W thin Be end window X-ray tube made by Varian company, Rh anode (Pd anode optional) 
Measurable elements: 10 arbitrary elements from Na to U. 
Detector: gas flow proportional detector + sealed proportional detector; 10 paths 1024 channels independent pulse height analyzer
Vacuum system: independent pumping station for easy maintenance with highest vacuum lower than 5 Pa 
Gas flow system: high-accuracy gas density stabilizer with pressure stability up to ±0.003 KPa. 
MCA: MCA measures the peak of every element in real time, which is not only good for instrument debugging and failure diagnosis but also enhance its analysis accuracy and stability. 
AC 220V power supply: 1KVA AC purified stabilized voltage power supply 
Analysis accuracy: oη-1 (24 hours,percentage content) ≤0.05 %.
Temperature control precision in constant temperature chamber: setting value士0.1°C.