TR-TC 9000 X-ray Fluorescence Spectrometer


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

Your present location: Home > Product> Laboratory Instrument> XRF> EDX>
  • Name: TR-TC 9000 X-ray Fluorescence Spectrometer
  • Model : TR-TC 9000
  • Erp code: 9000000137
  • | Share

TR-TC 3000D .jpg


Performance characteristics:

 RAPID, PRESENT TEST RESULTS IN 1 SECOND!

 1.The most advanced detection technology — Silicon Drift Detector(SDD), with resolution as low as 125eV

Advantage: large detecting area (25mm2); receiving more information in unit time; better count rate and resolution; higher precious metal detection efficiency; better SNR and lower detection limit

 2.The most advanced digital multichannel technology

Advantage: effectively improve output efficiency, realize ultra high counting rate, guarantee effective counting rate higher than 300KCPS

 3.Large power X ray tube and sophisticated collimation filter system

Advantage: higher excitation efficiency for precious metals

 4.Optical shutter system

Advantage: no need to close high voltage when replacing sample; improve test efficiency and accuracy

 Fine positioning system

Ultra-HD industrial camera shows test points more clearly

Multi-point test

2D movable sample platform – supports image coordinated control, multi-point continuous test

Tiny sample detection – minimum 0.2mm

8 collimators and 4 filters provide free selection according to different sample

The smallest 0.2 mm collimator allows detecting tiny sample

It identifies 99.9% and 99.99% pure gold effectively

It can detect hazardous elements in precious metals like Pb, Cd

 

 Technical Parameters:

 Analytical range: from S to U

Stability (RSD): 0.02%

Detector: X-Silicon Drift Detector (X-SDD)

Resolution: ≤ 135eV

Tube current: ≤1000uA

Tube voltage: 5~50kV

Measuring time: 1s (default)

Filter: 4 filters

Collimator: 8 collimators

Sample observation: HD industrial camera

Humidity: ≤70%

Temperature: 15℃~30℃

Input voltage: AC 220V±5V (suggest to use AC stabilizer)


 Technical Parameters

 Analytical range: from S to U

Stability (RSD): 0.02%

Detector: X-Silicon Drift Detector (X-SDD)

Resolution: ≤ 135eV

Tube current: ≤1000uA

Tube voltage: 5~50kV

Measuring time: 1s (default)

Filter: 4 filters

Collimator: 8 collimators

Sample observation: HD industrial camera

Humidity: ≤70%

Temperature: 15℃~30℃

Input voltage: AC 220V±5V (suggest to use AC stabilizer)