TR-TC-265H-2 Automatic Kinematic Viscometer


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TC-265H-2 Automatic Kinematic Viscometer
  • Model : TR-TC-265H-2
  • Erp code: 8000000023
  • | Share

Summary:
    The instrument is designed and made as per national standard of People’s Republic of China GB/T1632 Standard Test Method for Viscosity Number and Limiting Viscosity Number of Polymers in Dilute Solution. It is suitable to determine Kinematic viscosity, viscosity number, and limiting viscosity number of oils and polymer in dilute solution. It has been widely used in the field of pharmaceutics, petroleum, chemistry, scientific research, and metrology.
 
Main technical features:
1. Automatic and multifunctional. It is used to determine the viscosity of petroleum products and dilute solution of polymers. 
2. SCM technology. Automatic temperaturing, sampling, determining, cleaning,drying and data transmitting. 
3. Equipped with a notebook PC. All procedures including test control, calculation, result analyzing, data printing and saving can be operated on the PC. Easy to use.
4. Ubbelohde viscometers are equipped which have Self-detect function. No need to change viscometers during the test. The test items can be selected on menu of PC. 
5. A special low-temperature circulatory water bath is optional for low temperature viscosity tests.
 
Main technical specifications:
1.Viscometer tube:        Ubbelohde viscometer (Dilution type). As per GB/T1632-93  
2. Measuring precision:  As per GB/T265, GB/T1632-93
3. Temperature range:    Ambient to 100.0℃(A special low-temperature circulatory water bath is optional for low temperature viscosity tests.)
4. Temperature control accuracy:  ±0.01℃
5. Timing accuracy:  ±0.01s
6. Timing range:     0.0s~ 999.9 s
7. Power supply:   (220±10%)V,50Hz
8. Maximum power consumption:  1000W
9. Ambient temperature:   (0~40)℃
10. Relative humidity:       (20~80)%
11. Barometric pressure:  (96~103)kPa
12. Dimension:   570㎜×470㎜×510㎜Circulatory bath, vacuum suction apparatus

13. Net weight:   22.5kg(Circulatory bath, vacuum suction apparatus and PC are not included)


SYD-265H-2.jpg


Main technical specifications
1.Viscometer tube:        Ubbelohde viscometer (Dilution type). As per GB/T1632-93  
2. Measuring precision:  As per GB/T265, GB/T1632-93
3. Temperature range:    Ambient to 100.0℃(A special low-temperature circulatory water bath is optional for low temperature viscosity tests.)
4. Temperature control accuracy:  ±0.01℃
5. Timing accuracy:  ±0.01s
6. Timing range:     0.0s~ 999.9 s
7. Power supply:   (220±10%)V,50Hz
8. Maximum power consumption:  1000W
9. Ambient temperature:   (0~40)℃
10. Relative humidity:       (20~80)%
11. Barometric pressure:  (96~103)kPa
12. Dimension:   570㎜×470㎜×510㎜Circulatory bath, vacuum suction apparatus

13. Net weight:   22.5kg(Circulatory bath, vacuum suction apparatus and PC are not included)


No.

Item

Unit

Qty

Remarks

1

PC

Set

1


2

Vacuum suction device

Set

2


3

Optical components viscometer

(Inner diameter of 0.8 mm and 1.5 mm and 1.0mm,1.2mmeach one)

Set

A total of 4


4

Washing liquid pipe

Piece

2


5

Power supply wire (250V 10A)

Piece

1


6

Fuse (Φ5 × 20,10A)

Piece

2



0