TR-DX3600H Alloy Analyzer


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

Your present location: Home > Product> Laboratory Instrument> XRF> EDX>
  • Name: TR-DX3600H Alloy Analyzer
  • Model : TR-DX3600H
  • Erp code: 9000000113
  • | Share

TR-DX3600H .jpg


Performance characteristics:

l  Made in USA, halogen testing, X-ray tube of high efficient; the specification reaches the international advanced level.

l  Special accessories are developed for testing halogen element (especially chlorine element)

l  S100 detector, excellent energy linearity, energy resolution and energy spectrum characteristics. Higher peak-to-background ratio.

l  The instrument patent product- Signal-Noise-Enhancer (SNE) improves the signal processing ability up to 25 times.

l  Low energy X-rays are used, delivering good results when exciting light elements such as CI, Br.

l  Intelligent pumping vacuum system; shield air influence and enlarge testing scope.

l  Auto spectrum stabilizer ensures the instrument working.

l  High SNR electronic circuit unit

l  Auto collimator and filter switch, exempt from trouble by manual.

l  Spectrum unfolding technology decomposes the spectrum peak; ensuring CI, Br and other light elements testing have the equal analysis accuracy.

l  Multiple linear regression, reducing the inter elemental absorption and enhancement effect

l  In-built CCD with high resolution

l  LCD makes the important parameter (tube voltage, tube current, vacuum) of the instrument obvious.

 

Technical specifications:

Element contents: 1ppm—99.99%

Ability of simultaneous analysis: Simultaneously analysis of 24 elements.

Plating thickness: up to 0.005um each layer; it is able to analyze plating with more than 3 layers.

Analysis accuracy: 0.05%

Measurement time: 60s-200s

Energy resolution: (150±5)eV

Tube voltage: 5KV-50KV

Tube current: 50uA-1000uA

Forms of samples: powder, solid and liquid


Technical specifications

 Element contents: 1ppm—99.99%

Ability of simultaneous analysis: Simultaneously analysis of 24 elements.

Plating thickness: up to 0.005um each layer; it is able to analyze plating with more than 3 layers.

Analysis accuracy: 0.05%

Measurement time: 60s-200s

Energy resolution: 150±5eV

Tube voltage: 5KV-50KV

Tube current: 50uA-1000uA

Forms of samples: powder, solid and liquid