TR3332 High temperature differential thermal analyzer


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR3332 High temperature differential thermal analyzer
  • Model : TR3332
  • Erp code: 9000000093
  • | Share

TR3332.jpg


Product introduction:
Our company self-developed thermal analyzer series products are mainly oriented to industrial users, scientific research and teachingwidely used in all kinds of materials and product research and development in chemical field
process optimization and new quality inspection, etc, mainly measuring heat-related physical and chemical changes, such as physical melting point, crystallization melting hot phase crystallization heat, heat, heat stability (oxidation induced phase), glass transition temperature, etc.
 
 

Technical parameters:
1. The temperature range: room temperature ~ 1600 ℃
2. measuring range:  0
~±2000μV
3. DTA precision: ±0.1μV
4. Heating rate: 1 ~ 80 ℃ / min
5. Temperature resolution: 0.1℃
6. Temperature 0.1 ℃ accuracy: ±0.1℃
7. Temperature repeatability: ±0.2℃
8. Temperature control:
Warming temperature: program control 
(User can adjust parameters according to requirements)
Cooling temperature: air-cooled program control
(User can select from semiconductor cooling system, liquid nitrogen cooling system and so on.)
Constant temperature: program control (User can set the time arbitrarily)
9. Body Structure: Use the structure of the cover to replace the traditional lifting furnace, with high precision and easy operation.
10. Atmosphere control: (optional) gas flow meter, atmosphere conversion device
11. Data interface: RS - 232 serial communication supporting data and operating software
12. Display: Chinese Characters Big LCD Screen (mask LCD)
13. Parameters of Standard: Equipped with standard.
(User can correct the temperature)
14. Baseline adjustment: Users can adjust the baseline by changing baseline slope and intercept                   

15. Work power: AC 220V 50Hz


Technical parameters: 
1. The temperature range: room temperature ~ 1600 ℃
2. measuring range:  0~±2000μV
3. DTA precision: ±0.1μV 
4. Heating rate: 1 ~ 80 ℃ / min
5. Temperature resolution: 0.1℃ 
6. Temperature 0.1 ℃ accuracy: ±0.1℃ 
7. Temperature repeatability: ±0.2℃ 
8. Temperature control:
Warming temperature: program control  
(User can adjust parameters according to requirements)
Cooling temperature: air-cooled program control
(User can select from semiconductor cooling system, liquid nitrogen cooling system and so on.)
Constant temperature: program control (User can set the time arbitrarily)
9. Body Structure: Use the structure of the cover to replace the traditional lifting furnace, with high precision and easy operation.
10. Atmosphere control: (optional) gas flow meter, atmosphere conversion device
11. Data interface: RS - 232 serial communication supporting data and operating software
12. Display: Chinese Characters Big LCD Screen (mask LCD)
13. Parameters of Standard: Equipped with standard.
(User can correct the temperature)
14. Baseline adjustment: Users can adjust the baseline by changing baseline slope and intercept                   

15. Work power: AC 220V 50Hz