TR-TC2008D Intelligent Full-automatic Wide Distribution Wet Laser Particle Size Analyzers


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TC2008D Intelligent Full-automatic Wide Distribution Wet Laser Particle Size Analyzers
  • Model : TR-TC2008D
  • Erp code: 9000000068
  • | Share

TR-TC2008D .jpg


 

Measurements: 

Particles of different sizes scatters the illuminating laser in different patterns. In this instrument He-Ne laser is used to illuminate and photon detector arrays measure the forward, sideward and backward scattered laser. Software automatically converts the patterns into size distributions.
 Novel technique: It uses a patented technique of Fourier transform of converging light and the design of perpendicular light paths. Photon detector arrays measure the forward, sideward and backward scattered laser. This ensures the precision and reproducibility of the measurement results obtained from nano-particles.
 Intelligent measurements: Users only need to add in their samples, and click the ‘automatically measure’, and then all the procedures, including pumping in water, dispersing, circulation, measuring, cleaning, data recording, analyzing, saving and printing etc. are automatically executed. This reduces users’ workload, as well as minimizes any possible errors resulted from manual operations.
 Built-in dispersing system: We carefully aligned the stirring set-up, the ultrasonic dispersing unit and the sample circulation pipes, and fixed them inside the instrument. Such a built-in design effectively prevents the inhomogeneous dispersion and sedimentation of big particles, which can be observed in the designs that these dispersing units are separated from the instruments, where the sample circulation pipes are therefore too long.
 Unconstrained data fitting program: the particle analysis software uses a unique unconstrained data fitting technique that we developed to intelligently measure an unknown size distribution, this is particularly important for material researchers, or for measuring particle size distributions with multiple peaks in data.
 Automatic alignment: A precise four phase hybrid stepping motor automatically aligns the optical path and can adjust it at any moment. This releases users from manual adjusting the optical path and improved accuracy and stability of the measurement results.
 Micro sample chamber: The capacity of the micro sample chamber is as small as only 10ml. This helps with measuring expensive/precious samples, or samples difficult to be dispersed within medium.
 Rich software functions: Beside the basic function of analyzing the size distributions, the software also has the following features:
 The output has rich content including: size distribution, R-R distribution, logarithmic distribution, statistics within different size ranges, volume distribution, number distribution, the percentage of particles of a certain size, or a certain size range, and comparison of multiple results.
 The output could be in Word, Excel, Bmp pictures and Text formats, and this makes easy viewing and referencing the results at different situations.
 It supports English and Chinese languages, and it can be changed to many other language versions according to the user’s needs.
  Calibration: Throughout the measurable size ranges the instrument is calibrated with China’s standard reference particulate materials. The resolution and accuracy are guaranteed.

 

Specifications:

Model

TR-TC2008D 

PSA2008D

Measurement range

0.05-2000μm

0.05-1200μm

Number of channels

136

134

Dispersing media

distilled water, alcohol and other transparent liquids

Execution standard

ISO13320,GB/T19077.1-2008,Q/JW001-2006

Sample dispersing

ultrasonic dispersing time: 1-4mins

stirring speed: 0-500rpm

Accuracy

<3%( standard reference material)

reproducibility

<3%( standard reference material)

Dispersing methods

Circulation

Ratedflow:17L/min Rated power:15W

ultrasonic

Frequency: 40KHz, Power: 50W, Time: 0-10min

stirring

0-300rpm

Circulation

8L/min, 10W

Sample chamber

500ml

Micro sample chamber (optional)

10ml

Operating mold

Full-automatic, automatic centering

Operating time

<3mins

Laser

He-Ne λ=632.8nm, power>2mW

Power Source

ac 220/110v 50/60hz

Dimension

920mm×440mm×500mm

Weight

50kg

 

Shipping Package:

Name

Quantity

PSA2008 Laser particle analyzer

1

Laser particle analyzer software

(including Encryption dog)

1

Standard Reference material

1 bottle

Gears

1 set

Signal cable

2

Power cable

2

USB conversion line

2

 

Applications:

 For measurements performed on cements, ceramics ,drugs, coatings, dyes, paints, fillers, chemicals, catalysts, abrasives, lubricants, coal powder, muds and sands, dusts, cells, bacteria, foods, additives, pesticides, explosives, graphite, photosensitive materials, fuels, metal and non-metal powders, calcium carbonate, kaolinite, water and coal slurry, and other powdery materials. 


Specifications

Model

TR-TC2008D 

PSA2008D

Measurement range

0.05-2000μm

0.05-1200μm

Number of channels

136

134

Dispersing media

distilled water, alcohol and other transparent liquids

Execution standard

ISO13320,GB/T19077.1-2008,Q/JW001-2006

Sample dispersing

ultrasonic dispersing time: 1-4mins

stirring speed: 0-500rpm

Accuracy

<3%( standard reference material)

reproducibility

<3%( standard reference material)

Dispersing methods

Circulation

Ratedflow:17L/min Rated power:15W

ultrasonic

Frequency: 40KHz, Power: 50W, Time: 0-10min

stirring

0-300rpm

Circulation

8L/min, 10W

Sample chamber

500ml

Micro sample chamber (optional)

10ml

Operating mold

Full-automatic, automatic centering

Operating time

<3mins

Laser

He-Ne λ=632.8nm, power>2mW

Power Source

ac 220/110v 50/60hz

Dimension

920mm×440mm×500mm

Weight

50kg

 

Shipping Package

Name

Quantity

PSA2008 Laser particle analyzer

1

Laser particle analyzer software

(including Encryption dog)

1

Standard Reference material

1 bottle

Gears

1 set

Signal cable

2

Power cable

2

USB conversion line

2

 


0