TR-TC-Q9703 Automatic Calorimeter (Up and Down)


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

Your present location: Home > Product> Coal&Steel Testing> Calorimeter>
  • Name: TR-TC-Q9703 Automatic Calorimeter (Up and Down)
  • Model : TR-TC-Q9703
  • Erp code: 2000000003
  • | Share

TR-TC-Q9703.jpg

TR-TC-Q9703-1.jpg

Application area:

It is applicable in the industry such as electrical power, coal, papermaking, petrochemical, cement, farming, medical research, and instruction to measure the Calorific Value of combustible materials.


Technical parameters:

Calorimeter type: Isoperibol
Temperature range: 5℃~40℃
Temperature resolution: 0.0001℃
Precision (Precision Mode): RSD≤0.1%
Testing time (Precision Mode): 8 min
Power Supply: 220V, 50/60HZ
Power: ≤1.5kw
Weight: 55kg
Dimension: 630mm× 420mm× 450 mm


Features:

1.CE Certificated;

2. With the semi-conductor water refrigeration system, the instrument can automatically determinate the refrigerating capacity and balance the circulation system according to the caloric of previous time. Thus the water temperature can be kept constant, and the influence of environment can be greatly reduced. Perfectly solved the problem that the tests cannot be made continuously after 4-5 tests have been made because the temperature difference between outer bucket water and environment exceeds 1.5℃.

3.There is no need to measure water and adjust water temperature in the whole experiment, thus to make manipulation easy and convenient.

4. With auto descending and ascending oxygen bomb. Low malfunction rate.

5. With advanced small oxygen filling instrument. Low malfunction rate.

6. Probe-type electronic measuring cup is used to measure the inner bucket water, repetition error is less than 0.5g, so the water quantity is more accurate and the testing time is shorter.

7. With the high-efficiency magnetic force churning facility, the water in the inner bucket convect more quickly, so the main testing period is more stable.

8. The special auto stop and auto draining joints are equipped to change the water. When the drainpipe is connected, the instrument discharge water; when the drainpipe is taken off, the water will stop effusing.

9. Using the advanced USB technology, one computer can control 1-4 calorimeter buckets or other instruments, thus to make up synthesized testing instrument.

10.Completely support Windows systems; high stability; can link electronic scale and share data in long distance through network.


Technical parameters:

Calorimeter type: Isoperibol
Temperature range: 5℃~40℃
Temperature resolution: 0.0001℃
Precision (Precision Mode): RSD≤0.1%
Testing time (Precision Mode): 8 min
Power Supply: 220V, 50/60HZ
Power: ≤1.5kw
Weight: 55kg
Dimension: 630mm× 420mm× 450 mm


0