TR-TC-2801F Low-Temperature Penetrometer


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

Your present location: Home > Product> Highway&Geology Instrument> Penetration>
  • Name: TR-TC-2801F Low-Temperature Penetrometer
  • Model : TR-TC-2801F
  • Erp code: 6000000012
  • | Share

Summary:
    This instrument is designed and made as per T0604-2011 Penetration Test for Bituminous Materials in JTG E20-2011 Standard Test Methods for Bitumen and Bituminous Mixtures for Highway Engineering and ASTM D5 Standard Test Method for Penetration of Bituminous Materials. It is used to determine the penetration of pavement petroleum asphalt, modified asphalt, liquid petroleum asphalt and emulsified asphalt. It is also suitable to test solid particle, powder, colloid and raw-food materials such as cheese, glycine, butter, cream and leavening. It can be widely used in food industry, highway engineering and other industrial fields.
 
Main technical features:
1. It adopts digital display to show the penetration number and two grades of timing control.
2. Specially designed low-temperature circulatory water bath can supply the constant temperature water into glass bath on the penetrometer. It creates a constant low temperature which can be preset for the specimen.
 
Main technical specifications:
1. Circulatory water bath
    (1)Power supply: AC20V±10%, 50Hz
    (2)Bath volume: 8.5L
    (3)Temperature range: (5.0~100.0)℃
    (4)Temperature accuracy: ±0.1℃
    (5)Circulatory water quantity:  5L/min
    (6)Pump lift: 1m
    (7)Maximum power consumption: 1000W
    (8)Dimension: 420mm×380mm×900mm
2. Penetrometer
    (1)Timing controller: 5s or 60s can be selected. Bias within±0.1s
    (2)Needle holder:  High accuracy digital display. Easy to use and observe. It can be moved to any position.
    (3)Resolution: 0.01m
    (4)Penetration accuracy: ±1 penetration
    (5)Maximum scale: 600 penetrations
    (6)Standard needle: 50mm, 2.5g±0.05g
    (7)Dimension: 280mm×350mm×700mm



SYD-2801F.jpg

Main technical specifications
1. Circulatory water bath
    (1)Power supply: AC20V±10%, 50Hz
    (2)Bath volume: 8.5L
    (3)Temperature range: (5.0~100.0)℃
    (4)Temperature accuracy: ±0.1℃
    (5)Circulatory water quantity:  5L/min
    (6)Pump lift: 1m
    (7)Maximum power consumption: 1000W
    (8)Dimension: 420mm×380mm×900mm
2. Penetrometer
    (1)Timing controller: 5s or 60s can be selected. Bias within±0.1s
    (2)Needle holder:  High accuracy digital display. Easy to use and observe. It can be moved to any position.
    (3)Resolution: 0.01m
    (4)Penetration accuracy: ±1 penetration
    (5)Maximum scale: 600 penetrations
    (6)Standard needle: 50mm, 2.5g±0.05g
    (7)Dimension: 280mm×350mm×700mm



 

No.

Item

Unit

Qty

Remarks

1

Low temperature constant temperature bath

Set

1


2

Standard needle(50mm,2.5g±0.05g)

Piece

3


3

Weight (50g)

Piece

1


4

Asphalt sample container

Φ55 × H35 (small sample container)

Piece

3


Φ70 × H45 (big sample container)

Piece

3

Selection of accessories

Φ55 × H70 (special sample container)

Piece

3

Selection of accessories

5

Mercury thermometer (0~50 ℃, scale division is 0.1 ℃)

Piece

1


6

Needle connecting rod

Set

1


7

Heat preservation water sink(Heat preservation bath)

Piece

1


8

Black rubber hose

Piece

2


9

Hose clamp (Ф16 wire hoop)

Piece

4


10

Triangle holder

Piece

1


11

Fuse (2A, Ф5 × 20)

Piece

3

Used for penetration

Instrument.

12

Fuse (10A, Ф5 × 20)

Piece

2

Used for low temperature water bath.

13

Monitor battery(LR44,1.5V button batteries, Φ11.5 × thickness of 5)

Piece

1



0