TR-TC-2801C Penetrometer (With Constant Temperature Bath)


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

Your present location: Home > Product> Highway&Geology Instrument> Penetration>
  • Name: TR-TC-2801C Penetrometer (With Constant Temperature Bath)
  • Model : TR-TC-2801C
  • Erp code: 6000000011
  • | Share

Summary:
    The instrument is designed and made as per the national standard of People’s Republic of China GB/T 4509-1998/2010 Standard Test Methods for Penetration of Bitumen , GB/T269 Standard Test Methods for Cone Penetration of Lubricating Grease and Petrolatum and ASTM D217 Standard Test Methods for Cone Penetration of Lubricating Grease as well as T0604-2011 Bitumen Penetration Test in the industrial standard of People’s Republic of China JTG E20-2011 Specifications and Test Methods of Bitumen and Bituminous Mixture for Highway Engineering. It is suitable for the asphalt penetration test and grease (or oil fat) cone into the degree of testing. The instrument can also be used for solid granule, powder, colloid, frozen materials such as body, and cheese, sugar, butter, wheat the spray, cream, fermentation and other food raw material inspection, in the food industry, transportation, highway engineering and other industries can be widely used.
 
Main technical features:
1. Digital display shows the penetration value, eye-catching visual.
2. There are 6 files in the time control device, and the accuracy is high.
3. With functions of mast coarse and fine tuning, convenient adjustment, accurate to needle.
4. Equipped with a pounding fat machine, constant temperature bath, water bath temperature automatic control, multi-usage, instrument is cost-effective.
5. Selection of standard needle, sample dish, thermometer and weight and other different configurations, can be suitable for the national standard 4509-1998 GB/T, 4509-2010 GB/T and E20-2011 T0604-2011 in the measurement of JTG standards
 
The greatest features of this instrument are: advanced mechanical design, easy lift adjustment; digital temperature control table, temperature control is accurate; penetration of digital test of high precision, reliable measurement results.
 
Main technical specifications:
1. Measurement range: (0~600)penetration
2. Timing device: you can select 5 s, 8 s, 10 s, 12 s, 30 s, and 60 s; Timing error is less than ±0.1 s;
3. Resolution: 0.01 mm;
4. Penetration accuracy: ±1 penetration;
5. Standard needle: 50㎜、2.5g±0.05g
6. Heater power: 200 W;
7. Temperature control accuracy: 25±0.1 ℃ (Note: The ambient temperature shall not be higher than 20 ℃);
8. Temperature control mode: by a high precision digital temperature controller;
9. Constant temperature bath: Hard glass bath;
10. Bath stirring: automatically stirred by a magnetic stirrer;
11. Standard cone: 102.5±0.05 g, as per GB/T269 and ASTM D217;
12. Lifting support: With coarse and fine adjustment functions; it is used to let the needle point just touch the sample surface.
13. Power Supply: AC (220 ± 10%) V, 50Hz, power consumption is not more than 300W.
14. Dimensions: 280mm × 350mm × 700mm (length × width × height).
15. Others: Equipped with a cold light source and a magnifier. It is convenient for instrument operation.


SYD-2801C.jpg

Main technical specifications
1. Measurement range: (0~600)penetration
2. Timing device: you can select 5 s, 8 s, 10 s, 12 s, 30 s, and 60 s; Timing error is less than ±0.1 s;
3. Resolution: 0.01 mm;
4. Penetration accuracy: ±1 penetration;
5. Standard needle: 50㎜、2.5g±0.05g
6. Heater power: 200 W;
7. Temperature control accuracy: 25±0.1 ℃ (Note: The ambient temperature shall not be higher than 20 ℃);
8. Temperature control mode: by a high precision digital temperature controller;
9. Constant temperature bath: Hard glass bath;
10. Bath stirring: automatically stirred by a magnetic stirrer;
11. Standard cone: 102.5±0.05 g, as per GB/T269 and ASTM D217;
12. Lifting support: With coarse and fine adjustment functions; it is used to let the needle point just touch the sample surface.
13. Power Supply: AC (220 ± 10%) V, 50Hz, power consumption is not more than 300W.
14. Dimensions: 280mm × 350mm × 700mm (length × width × height).

15. Others: Equipped with a cold light source and a magnifier. It is convenient for instrument operation.



No

Item

Unit

Qty

Remark

1

Grease worker

Set

1


2

Bimetal thermometer and holder

Piece

1


3

Standard needle——By Table 1 configuration

——

——


4

Weight——By Table 1 configuration

——

——


5

Sample dish——By Table 1 configuration

——

——


6

Mercury thermometer——By Table 1 configuration

——

——


7

Cone penetration sample vessel

Piece

1


8

O type ring (Ф105×5) ——Mounted on a large sample  device

Piece

1


9

Standard Cone

Piece

1


10

Needle link

Piece

1


11

Glass sinks

Set

1


12

2A fuse  (Ф5 × 20)

Piece

1


13

Tripod

Piece

1


14

Magnetic stirring

Piece

1


15

Monitor battery (LR44,1.5V button batteries, φ11.5 × thickness of 5)

Grain

1


 

Table 1 Instrument configuration table with accessories

Item

GB/T 4509-1998Standard

GB/T 4509-2010Standard

T0604-2011 in JTG E20-2011 standard

Standard needle

50㎜,2.5g±0.05g

3Pieces

3Pieces

3Pieces

60㎜,2.5g±0.05g。

——

3Pieces

——

Sample dish

Φ55㎜×H16㎜

——

3Pieces

——

Φ55㎜×H35㎜

1Piece

3Pieces

3Pieces

Φ55㎜×H70㎜

Optional

3Pieces

Optional

Φ70㎜×H45

Optional

Optional

Optional

Thermometer

(0~50)℃、scale division is 0.1℃

1Piece

——

1Piece

(-8~32)℃、scale division is 0.1℃

——

1Piece

——

(25~55)℃、scale division is 0.1℃

——

1Piece

——

Weight

50g

2Pieces

1Piece

2Pieces

100g

——

1Piece

——


0