TR-TC-2806E Asphalt Softening Point Tester


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TC-2806E Asphalt Softening Point Tester
  • Model : TR-TC-2806E
  • Erp code: 6000000001
  • | Share

Summary:
    The instrument is designed and made as per the national standard of People’s Republic of China GB/T4507 Standard Test Method for Softening Point of Asphalt and T0606 Asphalt Softening Point Test (Ring and Ball Methods) in the industrial standard of People’s Republic of China JTG E20-2011 Standard Test Methods for Bitumen and Bituminous Mixtures for Highway Engineering.  It is suitable to determine the softening point of asphalt, tar, liquid asphalt and other types of asphalt. It is the best choice of asphalt manufacturers, highway and bridge construction companies, college and universities, and research and development departments.
    It adopts microcomputer control technology, linear heating and automatic stirring working mode, it can determine two samples at a time and can show test result automatically. It is convenient, efficient, and reliable. It is the desired instrument for laboratory to determine the softening point of asphalt.
 
Main technical specifications:
1. Power supply: AC 220V (-5%~10%), 50 Hz
2. Measurement range: 5.0 ℃~90±0.5 ℃; or 5.0 ℃~75±0.5 ℃ (You should use low temperature water for measurement at 5.0 ℃~ambient temperature)
3. Temperature resolution: 0.01 ℃
4. Stirrer: Its speed can be continuously adjusted
5. Heating rate: It will be 5.0±0.5 ℃/min after 3 minutes in the measurement state
6. Heating power: 800 W;
7. Capacity of beaker: 1000 ml
8. Environment: The working temperature should be lower than 35 ℃ and keep stable and without air convection
9. Relative humidity: ≤ 85%
10. Maximum power consumption: 850 W


SYD-2806E.jpg

Main technical specifications
1. Power supply: AC 220V (-5%~10%), 50 Hz
2. Measurement range: 5.0 ℃~90±0.5 ℃; or 5.0 ℃~75±0.5 ℃ (You should use low temperature water for measurement at 5.0 ℃~ambient temperature)
3. Temperature resolution: 0.01 ℃
4. Stirrer: Its speed can be continuously adjusted
5. Heating rate: It will be 5.0±0.5 ℃/min after 3 minutes in the measurement state
6. Heating power: 800 W;
7. Capacity of beaker: 1000 ml
8. Environment: The working temperature should be lower than 35 ℃ and keep stable and without air convection
9. Relative humidity: ≤ 85%
10. Maximum power consumption: 850 W



No.

Item

Unit

Qty

Remarks

1

Steel ball locator

Piece

2


2

Shoulder ring

Piece

2


3

Steel ball (Φ9)

Piece

2


4

Beaker

Piece

1


5

Stirring bar

Piece

1


6

Temperature sensor cable

Piece

1


7

6A fuse (Φ5×20)

Piece

2


 


0