TR-AHA-01 Automated Hematology Analyzer


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-AHA-01 Automated Hematology Analyzer
  • Model : TR-AHA-01
  • Erp code: 9000001079
  • | Share

TR-AHA-01.jpg


It is used to perform complete blood counts, erythrocyte sedimentation rates (ESRs), or coagulation tests.


Features

  1. Reliable and advanced technology.

  2. Safe and operated protection-environmental design.

  3. Computer and practical functions.

  4. Perfect calibration scheme of quality control.


Main technical

  • Working principle: Count by resistance method, SFT method without cyanide.

  • Testing parameter: Trisection of WBC, 23 parameters (including color histogram of WBC, RBC, PLT)

  • Sample dosage: Anticoagulation whole blood of 9.6ul, anticoagulation distal blood of 9.6ul, pre-dilution distal blood of 20ul.

  • Working mode: Counting channel testing plus independent hemoglobin testing system, continuous turning-0n of 24 hours, automatic dormancy and waking function.

  • Micro hole aperture: WBC: 100um. RBC/PLT: 80um

  • Storage of result: Automatic storage of all results of 120O0 pieces including 3 histograms.

  • Rate of crossed contamination:WBC、RBC、HGB<0.5%、PLT<1%

  • Index:       precision value      linear range

        WBC≤2.0%      0.0-99.9×109/L

        RBC≤1.5%       0.00-9.99×1012/L

        HGB≤1.5%       0-300g/L

        MCV≤0.4%      40-150fL

        PLT≤4.0%       0-999×109/L

        • Display screen: big-screen color liquid crystal display, 640x480 resolutions.

        • Interface: 1 parallel printing interface, 2 USB interface, 2 PS/2 interface, 2 RS232 interface (support networking).

        • Print report: Build-in high effective thermal sensitive printer, 8 choices of English report format, optical to multiple outside printers.

        • Working environment: temperature:10℃-35℃,humidity10%-90%,available in altiplano.

        • Power:AC220V 50Hz


        Main technical

        • Working principle: Count by resistance method, SFT method without cyanide.

        • Testing parameter: Trisection of WBC, 23 parameters (including color histogram of WBC, RBC, PLT)

        • Sample dosage: Anticoagulation whole blood of 9.6ul, anticoagulation distal blood of 9.6ul, pre-dilution distal blood of 20ul.

        • Working mode: Counting channel testing plus independent hemoglobin testing system, continuous turning-0n of 24 hours, automatic dormancy and waking function.

        • Micro hole aperture: WBC: 100um. RBC/PLT: 80um

        • Storage of result: Automatic storage of all results of 120O0 pieces including 3 histograms.

        • Rate of crossed contamination:WBC、RBC、HGB<0.5%、PLT<1%

        • Index:       precision value      linear range

              WBC≤2.0%      0.0-99.9×109/L

              RBC≤1.5%       0.00-9.99×1012/L

              HGB≤1.5%       0-300g/L

              MCV≤0.4%      40-150fL

              PLT≤4.0%       0-999×109/L

              • Display screen: big-screen color liquid crystal display, 640x480 resolutions.

              • Interface: 1 parallel printing interface, 2 USB interface, 2 PS/2 interface, 2 RS232 interface (support networking).

              • Print report: Build-in high effective thermal sensitive printer, 8 choices of English report format, optical to multiple outside printers.

              • Working environment: temperature:10℃-35℃,humidity10%-90%,available in altiplano.

              • Power:AC220V 50Hz