Big screen LCD display, English graphical interface touch screen input choosing to equip outlay mouse and keyboard simple and easy for operation.
The whole-new operation system, with integrated software of immunity analysis can make direct Chinese input of hospital management and patients' information.
8-channel optical fiber high speed scanning special center orientation for alisa hole leads to quick and correct measuring result.
Single-board multi-item testing, even 12 kinds qualitative or measurable testing can be done simultaneously on the same board.
Complete quality-control way, owning the function of LJ method X,S method and instant method and double quality-control function by multi-role can display, store print quality-control data and quality-control chart of each item
Visible and flexible board collocation, freely setting of position and quantity of blank comparison standard and sample.
The instruments can intelligently judge the state of blank comparison and standard according to the requirement of the program parameter.
Strong database can store 500 program parameters 200 thousand testing results and more than 2 years of quality-control data and quality-control chart, and freely display and print as well.
The CO value and standard curve of all items can be stored permanently and be called out and printed out momentarily.
Automatic single/double wavelength examination support many kinds of qualitative or measurable analytical models.
Support many kinds of built-in and outlay printers print the whole report, program report and quality-control and patient general report.
With the function of all-scale query and statistics convenient for the management of sections.
The intelligent resting protection function for prolonging the life-span of lamp.
The alisa workstation software can be chosen to equip with as well.
Sample form: 96 or 48 hole elisa board or strip.
Calculation mode: Absorbency, cut-off qualitative calculation. Single-point scahng, polyline regression, rnore-point percentage. Linear regression, index regression, log regression, power regression, double-log regression and Iog-Iogit regression.
Filter: Standard configuration with 4 light filters of 405,450,492,630nm,can reach to 8 light filters(according to clients' requirement)
Absorbance accuracy: ±0.01A
Absorbance repetition: ≤0.5%
Absorbance stability: ±0.005A
Testing speed: 5seconds/96holes
Linear error: ±0.5%
Display: LCD
Input way: Touching screen and pen
Interface: Serial port RS232, parallet port with printer