TR-SA3003A PSA3003A Full-automatic Dry Laser Particle Size Analyzers


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-SA3003A PSA3003A Full-automatic Dry Laser Particle Size Analyzers
  • Model : TR-SA3003A
  • Erp code: 9000000905
  • | Share

TR-SA3003A.jpg

TR-SA3003 is a new generation of automatic laser particle size analyzer for dry samples. The rational design and a new generation of dispersing units improved the dispersing performance by 1 degree of magnitude. It measures 0.1-500 micrometer particles without the need of changing measurement grade. The theoretical base of Mie light scattering theory, the technique of Fourier transformation of converging light, the stable He-Ne laser and the highly sensitive photon detector all ensure the reproducibility and the accuracy of the measurement result. The turbulent flow dispersing, together with an accurate sample feeding device and a patented powder spray pump, disperses samples homogenously. Any dry powders, particularly those reacting with the solvents or changing their shapes/sizes once diluted in the solvents, are suitable for measurements. The accuracy and the reproducibility are the same as those in wet-sample measurements. TR-SA3003 is for quality control and research in industries and academic institutes.


Main Features:

1) Unique patent technology of optical path and detection system, greatly improve testing resolution.

Converging Fourier transform optical path patent technology overcome lens aperture restriction on the scattering angle, expand testing range in limited space, and add more secondary integrated photodetectors, which can effectively collect scattered light from all angles in the the corresponding test range, make sure the testing accuracy and reliability within the full range.

2)Scientific and automatic dry dispersing system

Turbulence dispersion patented technology and Normal shock shearing effect make particles sufficient dispersion, dispersion core part using wearable ceramics not only improve dispersion system’s working life but ensure more accurate and stable testing result.

3)Intelligent Operation System realize one key test

Just need put in sample, Dust collection, air supply,feeding and others are all automatic. It only only  reduces workload, but eliminate errors caused by human factors, further improve testing accuracy and authenticity of the testing results.

4)Software support

Unique unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution, ensure accuracy of testing result.


Specifications:

Model

TR-SA3003A

TR-SA3003B

Measurement range

0.1-300μm

0.1-500μm

Number of channels

69

70

Execution standard

ISO13320GB/T19077.1-2008Q/JW001-2006

Accuracy

<3%( standard reference material)

reproducibility

<3%( standard reference material)

Dispersing way

Turbulent flow dispersing for dry samples

Operation mold

Manual, automatic

Measurement speed

<1min each operation

Laser

He-Ne λ=632.8nm, power>4mW

 

 

Shipping package:

Name

Quantity

PSA3003 Laser particle analyzer

1

PSA Laser particle analyzer software

including Encryption dog

1

Vacuum hover

1

Oil-free air compressor

1

Standard Reference material for measurements performed on dry samples

1 pouch

Gears

1 set

Signal cable

1

Power cable

2

 

 Applications: 

TR-SA3003 Dry laser particle size analyzer used in cement, ceramics, pharmaceuticals, dyes, pigments, fillers, chemical products, catalysts, coal dust, additives, pesticides, explosives, graphite, photographic materials, fuel, metal and nonmetal powder, carbonated calcium, kaolin and other powder industry, particularly for materials which occurs chemical reaction, the shape change and the loss in the liquid, such as herbs, magnetic materials and relatively wide distribution and larger particles powders, have more unique 

applicability and practicality.3003 3005 principle.PNG

PSA3003A-1.jpg

 

 

   


Specifications:

Model

TR-SA3003A

TR-SA3003B 

Measurement range

0.1-300μm

0.1-500μm

Number of channels

69

70

Execution standard

ISO13320GB/T19077.1-2008Q/JW001-2006

Accuracy

<3%( standard reference material)

reproducibility

<3%( standard reference material)

Dispersing way

Turbulent flow dispersing for dry samples

Operation mold

Manual, automatic

Measurement speed

<1min each operation

Laser

He-Ne λ=632.8nm, power>4mW

 

 

Shipping package:

Name

Quantity

PSA3003 Laser particle analyzer

1

PSA Laser particle analyzer software

including Encryption dog

1

Vacuum hover

1

Oil-free air compressor

1

Standard Reference material for measurements performed on dry samples

1 pouch

Gears

1 set

Signal cable

1

Power cable

2

 

 Applications: 

TR-SA3003 Dry laser particle size analyzer used in cement, ceramics, pharmaceuticals, dyes, pigments, fillers, chemical products, catalysts, coal dust, additives, pesticides, explosives, graphite, photographic materials, fuel, metal and nonmetal powder, carbonated calcium, kaolin and other powder industry, particularly for materials which occurs chemical reaction, the shape change and the loss in the liquid, such as herbs, magnetic materials and relatively wide distribution and larger particles powders, have more unique 

applicability and practicality.3003 3005 principle.PNG

PSA3003A-1.jpg

 

 

   