TR-SA2308A PSA2308A Intelligent Whole Range Dry and Wet Laser Particle Size Analyzers


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-SA2308A PSA2308A Intelligent Whole Range Dry and Wet Laser Particle Size Analyzers
  • Model : TR-SA2308A
  • Erp code: 9000000886
  • | Share

TR-SA2308A.jpg

TR-SA2308A is intelligent full automatic model which is integrated model of wet and dry system.  It’s the primary choice for industrial production quality control departments and research institutions  which have many types of particles and wide particle size distribution need test. Good performance model with multiple winner patented technology   


Main Features:

1)Wet and dry Integrated Design This instrument integrated wet and dry dispersion test in one, successfully resolved the problem of dry and wet technology integration, realize one key to switch.     

2) Intelligent full automatic operation system and manual operation, freely choose. Choose automatic mode, very easy and simple to learn,support one key operation.    

3) Optical Path System patented technology Converging light Fourier transform path system, enables scattering light be not restricted to the lens aperture limit, and the dual laser orthogonal light use auxiliary semiconductor laser to expand the measurement range by enlarge scattering angle from 45 degrees to 135 degrees.   

4) Automatic Optical path alignment System, which is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level,make optimum optical paths to ensure accurate and stable test.   

5) Full built-in Sample dispersion system. set mechanical stirring, ultrasonic dispersion, and circulation path in one, It ensures particles uniform dispersion and distribution,avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube,  And it guarantees the representativeness of test result.   

6)Instrument Software Original Unconstrained free fitting technology collect scattering data during the measurement process, make particle analysis not be restricted by any functions, truly reflect particles distribution.       


Software Function:   

1, Analysis Mode Free Distribution,R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.  meet different demands of particle size statistic in different industries.   

2,Statistic Method Volume Distribution, Quantity Distribution    

3,Statistic Comparison Statistic Several Testing Results to compare and analyze Get difference by compare test result of different batches of samples, samples  before and after processing,  and different time. Have great practical significance to industrial raw materials quality control    

4,User-defined Analysis Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries.   

5,Test Report Word, Excel,Photo( Bmp), Text etc.   

6,Multi-language Support Chinese&English (Others are available)   

7,Intelligent Operation Mode Automatically control water inflow, dispersion,test and analysis. Better Repeatability after remove human-factor   


Specifications :

Model

TR-SA2308A

TR-SA2308C

Measurement range

Dry way:1-2000μm

Wet way:0.05-2000μm

Dry way:1-1200μm

Wet way:0.1-1200μm

Number of channels

Dry way:100

Wet way:136

Dry way:98

Wet way:115

Dispersing

Dry samplesturbulent flow dispersingnormal shock wave dispersing

Wet samplesultrasonic dispersing and mechanical stirring

Execution standard

ISO13320GB/T19077.1-2008Q/JW001-2006

Sample dispersing

Ultrasonic time: 1-4mins

Stirring rate: 0-500rpm

Accuracy error

<3%( standard reference material)

reproducibility

<3%( standard reference material)

Dispersing methods

Circulation

Ratedflow:17L/min Rated power:15W

ultrasonic

Frequency: 40KHz, Power: 50W, Time: 0-10min

stirring

0-300rpm

Circulation

8L/min, 10W

Sample chamber

500ml

Micro sample chamber

10ml (optional)

Operating mold

Full-automatic

Operating time

<3mins each operation

Laser

He-Ne λ=632.8nm, power>2mW

Power Source

ac 220/110v 50/60hz

Dimension

920mm×440mm×500mm

Weight

70kg

 

Shipping package:

Name

Quantity

PSA2308 Laser particle analyzer

1

Laser particle analyzer software

including Encryption dog

1

Vacuum hover

1

Oil-free air compressor

1

Standard Reference material for measurements performed on dry samples

1 pouch

Standard Reference material

2 bottles

Gears

1 set

Signal cable

2

Power cable

2

USB conversion line

2

 

Application: 

TR-SA2308A widely used in cement, ceramics, medicines, lotions, paints, dyes, pigments, fillers, chemicals, catalysts, drilling mud, abrasives, lubricants, coal, sediment, dust, cells, bacteria, food additives, pesticides, explosives, graphite, photographic materials, fuel, ink, metal and non-metal powder, calcium carbonate, kaolin, coal slurry and other powdered materials.

 

 


Specifications: 

Model

TR-SA2308A

TR-SA2308C 

Measurement range

Dry way:1-2000μm

Wet way:0.05-2000μm

Dry way:1-1200μm

Wet way:0.1-1200μm

Number of channels

Dry way:100

Wet way:136 

Dry way:98

Wet way:115

Dispersing

Dry samplesturbulent flow dispersingnormal shock wave dispersing

Wet samplesultrasonic dispersing and mechanical stirring

Execution standard

ISO13320GB/T19077.1-2008Q/JW001-2006

Sample dispersing

Ultrasonic time: 1-4mins

Stirring rate: 0-500rpm

Accuracy error

<3%( standard reference material)

reproducibility

<3%( standard reference material)

Dispersing methods

Circulation

Ratedflow:17L/min Rated power:15W

ultrasonic

Frequency: 40KHz, Power: 50W, Time: 0-10min

stirring

0-300rpm

Circulation

8L/min, 10W

Sample chamber

500ml

Micro sample chamber

10ml (optional)

Operating mold

Full-automatic

Operating time

<3mins each operation

Laser

He-Ne λ=632.8nm, power>2mW

Power Source

ac 220/110v 50/60hz

Dimension

920mm×440mm×500mm

Weight

70kg

 

Shipping package:

Name

Quantity

PSA2308 Laser particle analyzer

1

Laser particle analyzer software

including Encryption dog

1

Vacuum hover

1

Oil-free air compressor

1

Standard Reference material for measurements performed on dry samples

1 pouch

Standard Reference material

2 bottles 

Gears

1 set

Signal cable

2

Power cable

2

USB conversion line 

2

 

Application: 

TR-SA2308A widely used in cement, ceramics, medicines, lotions, paints, dyes, pigments, fillers, chemicals, catalysts, drilling mud, abrasives, lubricants, coal, sediment, dust, cells, bacteria, food additives, pesticides, explosives, graphite, photographic materials, fuel, ink, metal and non-metal powder, calcium carbonate, kaolin, coal slurry and other powdered materials.

 

 



0