Oscilloscopes:
TRYTE are used in the sciences, medicine, engineering, telecommunications, and industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system, or to display the waveform of the heartbeat as an electrocardiogram.
Humanness Functions: |
| In order to protect the buttons and knobs on the instrument panel, avoid dust when storing. the instrument adds protection mask. | | The instrument designs the storage container storing manual and accessories, more convenient to users. |
Easy to read with color or monochrome (NST) LCD display
Dual channel,Bandwith 25 - 200MHz
Sample Rate(Real - time)500MHz up to 1GSa/s,Equivalent Sampling 50GSa/s.
4K channel memory depth.
Advanced Triggering function from edge,video,pulse,delay.
+ - × ÷ Mathematic Functions
FFT spectrum analysis:Hanning,Hamming,Blacking,Rectangle
Automatic Parameter Measurements:Vpp,Vamp,Vrms,Vmax,Vmin,Vtop,Vbase,
Vavg,Freq,Period,Risetime, Falltime, +Width,-Width,Overshoot,Preshoot,+Duty,-Duty,etc.
10 Waveforms parameter Setups,Save,Reall.
Vertical scale:2mV - 5V/div
Sweep time:1ns - 50s/div
Rise time:1.8ns - 14ns
Power supply:100 - 240V,45 - 65Hz,<50W
Dimensions:290(L)×330(W)×145(H)
Common Specifications:
Number of Channel: 2CH; Ext. Trig
Memory: 4K per channel
Vertical Sensitivity: 2mv/div-5v/div
Vertical Resolution: 8bits
Input Coupling: DC. AC. GND
Trigger Mode: Auto. Normal. Single
Trigger Type: Edge. TV. Pulse
Trigger Coupling: DC. AC. LF Rej. HF Rej
Horizontal Accuracy: ±0.01%
Math: + - × , FFT
FFT Window: Hanning. Hamming. Blackman. Rectangular
FFT Sample: 1024Points
Auto Measurement: Vpp. Vmax. Vmin. Vtop. Vbase. Vamp. Vrms. Vavg. Vover. Vpre
Freq. Period. Rise. Fall. +Width. -Width. +Duty. -Duty. DelayA. DelayB
Cursor Measure: Manual. Trace. Auto Measure
Storage: 10Wave forms.10 setups
I/O: USB device
Power: 100V-240V/50VA Max
Net Weight: 5kg
Size: 300(D) x312(W) x145(H)
Accessories: Probe x 2(1x.10x) Power Cord. User manual
Specifications:
Specifications | TR-OS-200B | TR-OS-150B | TR-OS-100B | TR-OS-60B | TR-OS-40B |
Bandwidth | 200MHz | 150 MHz | 100 MHz | 60 MHz | 40 MHz |
Real time Sample Rate | 1GS/S |
Equivalent Sample Rate | 50GS/S |
Input Impedance | 1MΩ//13pF 50Ω |
Rise time | 1.8ns | 2.3 ns | 3.5 ns | 5.8 ns | 8.8 ns |
Time base Range | 1ns/div-50s/div | 2ns/div-50s/div | 5ns/div-50s/div |
X-Y Operation | Bandwidth | 200MHz | 150 MHz | 100 MHz | 60 MHz | 40 MHz |
PhaseDHerence | ±3degrees |
Display | Color LCD(C)/Mono LCD(M)320x240 |
Specifications | TR-OS-150C | TR-OS-100C | TR-OS-60C | TR-OS-40C | TR-OS-25C |
Bandwidth | 150 MHz | 100 MHz | 60 MHz | 40 MHz | 25 MHz |
Real time Sample Rate | 500MS/S |
Equivalent Sample Rate | 50GS/S |
Input Impedance | 1MΩ//13pF 50Ω |
Rise time | 2.3 ns | 3.5 ns | 5.8 ns | 8.8 ns | 14ns |
Time base Range | 2ns/div-50s/div | 5ns/div-50s/div | 20ns/div-50ns |
X-Y Operation | Bandwidth | 150 MHz | 100 MHz | 60 MHz | 40 MHz | 25 MHz |
PhaseDHerence | ±3degrees |
Display | TFT/Color LCD(C)/Mono LCD(M)320x240 |
Common Specifications |
Number of Channel | 2CH;Ext.Trig |
Memory | 4K per channel |
Vertical Sensitivity | 2mv/div-5v/div |
Vertical Resolution | 8bits |
Input Coupling | DC.AC.GND |
Trigger Mode | Auto.Normal.Single |
Trigger Type | Edge.TV.Pulse |
Trigger Coupling | DC.AC.LF Rej.HF Rej |
Horizontal Accuracy | ±0.01% |
Math | + - × ,FFT |
FFT | Window | Hanning.Hamming.Blackman.Rectangular |
Sample | 1024Points |
Auto Measurement | Vpp.Vmax.Vmin.Vtop.Vbase.Vamp.Vrms.Vavg.Vover.Vpre Freq.Period.Rise.Fall.+Width.-Width.+Duty.-Duty.DelayA.DelayB |
Cursor Measure | Manual. Trace. Auto Measure |
Storage | 10Wave forms.10 setups |
I/O | USB device |
Power | 100V-240V/50VA Max |
Net Weight | 5kg |
Size | 300(D)x312(W)x145(H) |
Accessories | Probe x 2(1x.10x)Power Cord. User manual |