 TR-ON-P series are used to measure conductivity, total dissolved solid, salinity and temperature of solution.


Adjustable Temperature Coefficient:
Solution contained different ions usually have different temperature coefficient,  TR-ON-P series can be set in the range of 0 and 3.9% per centigrade degree.


Adjustable Cell Constant:
When measure solution with higher or lower concentration, you should choose different constant of conductivity electrode.
The meter with three cell constants for your choose, it can save the measured value for different constant electrode separately.
After setting the constant, you needn't calibrate it again when replacing a new electrode.


Adjustable TDS Coefficient:
According to the theory of electrical conductivity, you need estimate TDS coefficient when measure total dissolved solid of solution.
 TR-ON-P30/540 can be set in the range of 0.01 to 1.00, which can ensure accuracy of measured value.

Hold Function:
The meter with hold function, press MEAS/HOLD key, the meter momentarily freezes reading for easy viewing.

Message Indicator:
The meter with operational message indicator. When you need setup or measurement, the message indicator will help you what you can do and how do it. You can set parameter or select functions under it's guide.


Save Data:
The meter can save 64 data sets, press SAVE key, and the meter will store current measured value, serial number, date, time and other information.


Output Data:
The data can be sent to computer through USB Communication interface, you can print out test report via software.


What's included:
 TR-ON-P20: CON1 Conductivity electrode(K=1).
Temperature probe, Battery.
 TR-ON-P30/531/540: CON1 Conductivity electrode(K=1),
CON10 Conductivity electrode(K=10), Temperature probe, Battery.


Microprocessor-Based:
 TR-ON-P series has built-in high performance CPU, it can work about 200 hours continuously with 9 volt battery.


Single Point Push-Button Calibration:
The meter with single point calibration function, it is permitted to use standard conductivity solution, you need only set conductivity value of the calibration solution at 25OC and immerse conductivity electrode into solution, then press ENTER key, the meter will be calibrated automatically. 


Auto Standard Solution Recognition:
In calibration, the meter will display ERROR if you use conductivity solution by mistake.


Auto-Ranging for Conductivity:
The meter with auto-ranging function when measure conductivity or total dissolved solid. After electrode immersed in solution
 TR-ON-P series will fast response and convert range.


Auto Temperature Compensation:
The meter will recognize the temperature sensor automatically and measure temperature after temperature sensor connected to the host. If the conductivity electrode connected to it, the meter will enter automatic temperature compensation. 


The series include four models:
 TR-ON-P20 Conductivity/oC Meter
 TR-ON-P30 Conductivity/TDS/oC Meter
 TR-ON-P31 Conductivity/Salinity/oC Meter
 TR-ON-P40 Conductivity/TDS/Salinity/oC Meter


Specifications:

   Model
 TR-ON-P20 TR-ON-P30 TR-ON-P31 TR-ON-P40
    Conductivity Range
0~1.999, 19.99, 199.9, 1999uS/cm, 19.99, 199.9mS/cm
     Conductivity Accuracy
±0.5% F.S±0.5% F.S±0.5% F.S±0.5% F.S
    TDS Range
---0~Max.200ppt---0~Max.200ppt
    TDS Accuracy
---±1%  F.S---±1%  F.S
    TDS Conversion Factor
---0.01~1.00---0.01~1.00
    Salinity Range
------0.00~5.00%0.00~5.00%
    Salinity Accuracy
------±0.05%±0.05%
     Temperature Range
0~100oC
    Temperature  Accuracy
±1oC



    Calibration Points
1 Point
     Calibration Solution
146.6uS/cm, 1408uS/cm, 12.85mS/cm
     Temperature Compensation
0~50oC
    Temperature Coefficient
0~3.9%/oC
     Cell Constant
K=0.1, 1, 10, adjustable
    Memory
64 data sets


    Display
4.3' LCD


    Output

USB Communication interface

    Power Requirements
9V Battery
    Battery Life
Approx. 200 hours of continuous use
    Dimensions
185(L)mm×88(W)mm×32(H)mm
    Weight
300g



Specifications:


   Model
 TR-ON-P20 TR-ON-P30 TR-ON-P31 TR-ON-P40
    Conductivity Range
0~1.999, 19.99, 199.9, 1999uS/cm, 19.99, 199.9mS/cm
     Conductivity Accuracy
±0.5% F.S±0.5% F.S±0.5% F.S±0.5% F.S
    TDS Range
---0~Max.200ppt---0~Max.200ppt
    TDS Accuracy
---±1%  F.S---±1%  F.S
    TDS Conversion Factor
---0.01~1.00---0.01~1.00
    Salinity Range
------0.00~5.00%0.00~5.00%
    Salinity Accuracy
------±0.05%±0.05%
     Temperature Range
0~100oC
    Temperature  Accuracy
±1oC



    Calibration Points
1 Point
     Calibration Solution
146.6uS/cm, 1408uS/cm, 12.85mS/cm
     Temperature Compensation
0~50oC
    Temperature Coefficient
0~3.9%/oC
     Cell Constant
K=0.1, 1, 10, adjustable
    Memory
64 data sets


    Display
4.3' LCD


    Output

USB Communication interface

    Power Requirements
9V Battery
    Battery Life
Approx. 200 hours of continuous use
    Dimensions
185(L)mm×88(W)mm×32(H)mm
    Weight
300g




0