TR-LE-518 Bench top ion concentration meter


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-LE-518 Bench top ion concentration meter
  • Model : TR-LE-518
  • Erp code: 9000000750
  • | Share

TR-LE-518.jpg

 

Detailed Product Description

ion concentration meter 

Measuring Parameters: Ca2+,mV and Temperature 

ion concentration meter

Model: TR-LE-518Calcium Ion Concentration Mete

Measuring Parameters:

Ca2+ Concentration,mV,Temperature

 

Specifications:

Range:

Ca2+: (0.00 to 9.00)pCa       

Units:pCa,mol/L, mg/L and ppm

mV:±1999.9 mV

Temp: (-10 to 110)oC

 

Accuracy:

Ca2+: ±0.01 pCa    

mV:±0.1% mV

Temp:  ±0.5oC

 

Other Parameters:

ATC: (0 to 50)oC

Storage Data:600 groups;

Communication Connector:RS-232;

Power:DC9V/300mA;

Size & Weight:160×190×70mm/880g

 

What's included:

Model CA501 calcium ion combination electrode

TR-LE-500 temperature probe

Model 901 intelligent stirrer

Model 602 flexible electrode holder

RS-232 communication software

  

Features and Applications:

Use combination calcium electrode, has reliable performance and easy to use.

Two-point calcium ion concentration standard solution calibration, can directly test calcium ion concentration of sample.

Intelligent stirrer rotation speed can be set to be changeless, convenient and reliable.

Sampling measurement the calcium ion concentration in the water solution.


Specifications:

Range:

Ca2+: (0.00 to 9.00)pCa       

Units:pCa,mol/L, mg/L and ppm

mV:±1999.9 mV

Temp: (-10 to 110)oC

 

Accuracy:

Ca2+: ±0.01 pCa    

mV:±0.1% mV

Temp:  ±0.5oC

 

Other Parameters:

ATC: (0 to 50)oC

Storage Data:600 groups;

Communication Connector:RS-232;

Power:DC9V/300mA;

Size & Weight:160×190×70mm/880g

 

What's included:

Model CA501 calcium ion combination electrode

TR-LE-500 temperature probe

Model 901 intelligent stirrer

Model 602 flexible electrode holder

RS-232 communication software

 

Features and Applications:

Use combination calcium electrode, has reliable performance and easy to use.

Two-point calcium ion concentration standard solution calibration, can directly test calcium ion concentration of sample.

Intelligent stirrer rotation speed can be set to be changeless, convenient and reliable.

Sampling measurement the calcium ion concentration in the water solution.


0