TR-LE-517 Bench top ion concentration meter(sodium )


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-LE-517 Bench top ion concentration meter(sodium )
  • Model : TR-LE-517
  • Erp code: 9000000749
  • | Share

TR-LE-517.jpg


Detailed Product Description

ion concentration meter 

sodium Ion concentration meter 

ion concentration meter

sodium Ion concentration meter

TR-LE-517 Sodium Ion Concentration Meter


Range:

Na+: 0.00 to 9.00pNa       

Units:pNa, mol/L, mg/L and ppm

mV:±1999.9 mV

Temp: -10 to 110oC


Accuracy:

Na+: ±0.01pNa       

mV:±0.1% mV

Temp:  0.5oC


Other Parameters:

ATC: 0 to 50oC

Storage Data:600 groups;

Communication Connector:RS-232;

Power:DC9V/300mA;

Size & Weight:160×190×70mm/880g

 

Whats included:

Model 7801 sodium ion electrode

Model 6212-M reference electrode

TR-LE500 temperature probe

Model 901 intelligent stirrer

Model 602 flexible electrode holder

RS-232 communication software


Features and Applications:

Two-point sodium ion concentration standard solution calibration, can directly test sodium ion concentration of sample.

Intelligent stirrer rotation speed can be set to be changeless, convenient and reliable.

Lower limited of measuring value: static state test≥2ppb, flowing state test ≥0.2ppb, suitable for sampling measuring sodium ion concentration which exists in high purified water in electric factory


Range:

Na+: 0.00 to 9.00pNa       

Units:pNa, mol/L, mg/L and ppm

mV:±1999.9 mV

Temp: -10 to 110oC


Accuracy

Na+: ±0.01pNa       

mV:±0.1% mV

Temp:  0.5oC


Other Parameters:

ATC: 0 to 50oC

Storage Data:600 groups;

Communication Connector:RS-232;

Power:DC9V/300mA;

Size & Weight:160×190×70mm/880g

 

Whats included:

Model 7801 sodium ion electrode

Model 6212-M reference electrode

TR-LE500 temperature probe

Model 901 intelligent stirrer

Model 602 flexible electrode holder

RS-232 communication software


Features and Applications:

Two-point sodium ion concentration standard solution calibration, can directly test sodium ion concentration of sample.

Intelligent stirrer rotation speed can be set to be changeless, convenient and reliable.

Lower limited of measuring value: static state test≥2ppb, flowing state test ≥0.2ppb, suitable for sampling measuring sodium ion concentration which exists in high purified water in electric factory