TR-LE-519 Bench top fluoride Ion concentration meter


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-LE-519 Bench top fluoride Ion concentration meter
  • Model : TR-LE-519
  • Erp code: 9000000748
  • | Share

TR-LE-519.jpg

 

Detailed Product Description:

fluoride Ion concentration meter 

Bench top fluoride ion concentration meter 

Measuring Parameters: F- Concentration,mV and Te 

fluoride Ion concentration meter

Model TR-LE-519 Fluoride Ion Concentration Meter

Measuring Parameters:

F- Concentration,mV and Temperature

 

Specifications:

Range:

F-: 0.00 to 9.00pF   

Units : pF,mol/L, mg/L and ppm

mV:±1999.9 mV

Temp: (-10 to 110)oC

 

Accuracy:

F-: ±0.01pF       

mV:±0.1% mV

Temp:  ±0.5oC

 

Other Parameters:

ATC: (0 to 50)oC

Storage Data:600 groups;

Communication Connector:RS-232;

Power:DC9V/300mA;

Size & Weight:160×190×70mm/880g.

 

What's included:

Model F502 fluoride ion electrode

Model 6211-M reference electrode

TR-LE-500 temperature probe

Model 901 intelligent stirrer

Model 602 flexible electrode holder

RS-232 communication software

 

Features and Applications:

Two-point fluoride ion concentration standard solution calibration, can directly test fluoride ion concentration of sample,

Intelligent stirrer rotation speed can be set to be changeless, convenient and reliable,

Sampling measurement the fluoride ion concentration in the water solution.


Specifications:

Range:

F-: 0.00 to 9.00pF   

Units : pF,mol/L, mg/L and ppm

mV:±1999.9 mV

Temp: (-10 to 110)oC

 

Accuracy:

F-: ±0.01pF       

mV:±0.1% mV

Temp:  ±0.5oC

 

Other Parameters:

ATC: (0 to 50)oC

Storage Data:600 groups;

Communication Connector:RS-232;

Power:DC9V/300mA;

Size & Weight:160×190×70mm/880g.

 

What's included:

Model F502 fluoride ion electrode

Model 6211-M reference electrode

TR-LE-500 temperature probe

Model 901 intelligent stirrer

Model 602 flexible electrode holder

RS-232 communication software

 

Features and Applications:

Two-point fluoride ion concentration standard solution calibration, can directly test fluoride ion concentration of sample,

Intelligent stirrer rotation speed can be set to be changeless, convenient and reliable,

Sampling measurement the fluoride ion concentration in the water solution.


0