TR-OM-02 Precision Dissolved Oxygen Meter


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-OM-02 Precision Dissolved Oxygen Meter
  • Model : TR-OM-02
  • Erp code: 9000000742
  • | Share

TR-OM-02.gif

TR-OM980 precision dissolved oxygen meter are used to measure amount of gaseous oxygen dissolved in a liquids. 


Feature:

Two-point push-button calibration(Zero and 100%)

Automatic temperature compensation

Salinity and barometric pressure compensation

Multi-measurement units (mg/L/ppm; kPa/mmHg, etc.)

Automatic operation message prompts

Expanded memory stores and recalls up to 99 data sets

Built-in real-time clock stamps for stored data

USB Communication interface

 

What's included:
Meter, DO probe, Membrane cap, Electrolyte solution, Battery.

   Model
TR-OM980
    Dissolved Oxygen Range
0.00~20.00mg/L or ppm
    Resolution
0.01mg/L
    Dissolved Oxygen Accuracy
±0.3mg/L
    % Saturation of Oxygen
0.0~200.0%
     Accuracy
±5.00%
    Temperature Range
0.0~50.0oC, 32~122oF
    Temperature Accuracy
±1oC,  ±1.8oF
     Temperature Compensation
0.0~40.0oC, Automatic
    Salinity Correction
0~35g/L
     Barometric Pressure Correction
450~850mmHg, 60.0~112.5kPa
    Calibration Points
1 or 2 Points, 100% in air or 0% in solution
    Memory
99 data sets
    Output
USB Communication interface
    Power Requirements
DC9V, using AC adapters, 220VAC, 50Hz
    Dimensions
210(L)mm×188(W)mm×60(H)mm






Feature:

 Two-point push-button calibration(Zero and 100%)

 Automatic temperature compensation

 Salinity and barometric pressure compensation

 Multi-measurement units (mg/L/ppm; kPa/mmHg, etc.)

 Automatic operation message prompts

 Expanded memory stores and recalls up to 99 data sets

 Built-in real-time clock stamps for stored data

 USB Communication interface

 

What's included: 
Meter, DO probe, Membrane cap, Electrolyte solution, Battery.

   Model
TR-OM980
    Dissolved Oxygen Range
0.00~20.00mg/L or ppm
    Resolution
0.01mg/L
    Dissolved Oxygen Accuracy
±0.3mg/L
    % Saturation of Oxygen
0.0~200.0%
     Accuracy
±5.00%
    Temperature Range
0.0~50.0oC, 32~122oF
    Temperature Accuracy
±1oC,  ±1.8oF
     Temperature Compensation
0.0~40.0oC, Automatic
    Salinity Correction
0~35g/L
     Barometric Pressure Correction
450~850mmHg, 60.0~112.5kPa
    Calibration Points
1 or 2 Points, 100% in air or 0% in solution
    Memory
99 data sets
    Output
USB Communication interface
    Power Requirements
DC9V, using AC adapters, 220VAC, 50Hz
    Dimensions
210(L)mm×188(W)mm×60(H)mm