Detailed Product Description
conductivity meter, bench top conductivity meter, DO meter
Can choose resolution and accuracy of measuring
conductivity meter, bench top conductivity meter, DO meter
Model: TR-LE-526 Conductivity&DO Meter
Measuring Parameters:
Conductivity,Resistivity,TDS,Salinity,DO,Temperature.
Specifications:
Range:
Cond 0 to 2000 mS/cm,be divided into six ranges:
0.00 to 20.00μS/cm20.0 to 200.0μS/cm
200 to 2000μS/cm2.00 to 20.00mS/cm
20.0 to 200.0mS/cm200 to 2000mS/cmK=10
Res 0 to 100MΩ·cm
TDS 0 to 100g/L
Sal 0 to 100ppt
DO 0 to 40.00mg/L(ppm)0 to 200.0%
Temp: -10 to 110
Accuracy:
Cond ±0.5% full scale
DO ±0.10 mg/L
Temp: ±0.4oC
ATC
Cond 0 to 50oC
DO 0 to 45oC
Other Parameters:
Storage Data: 600 groups; Communication ConnectorRS-232;
Power:DC9V/300mA.
Whats included:
2401-M glass conductivity electrode K=1,ATC
DO500 dissolved oxygen electrode
Model 602 flexible electrode holder
Model 901 intelligent stirrer
RS-232 communication software
Features and Applications:
Conductivity and dissolved oxygen double-parameter meter with high accuracy.
Inside setup with function of high purified water non-linearity automatic temperature compensation, suitable for accurate conductivity measurement for high purified water.
New type dissolved oxygen electrode has function of salinity measurement, can automatic achieve salinity compensation and temperature compensation; meter inside with air pressure sensor, can automatic achieve air pressure compensation;
Polarographic type dissolved oxygen electrode, short polarization time, fast response and accurate measurement.
Specifications:
Range:
Cond 0 to 2000 mS/cm,be divided into six ranges:
0.00 to 20.00μS/cm20.0 to 200.0μS/cm
200 to 2000μS/cm2.00 to 20.00mS/cm
20.0 to 200.0mS/cm200 to 2000mS/cmK=10
Res 0 to 100MΩ·cm
TDS 0 to 100g/L
Sal 0 to 100ppt
DO 0 to 40.00mg/L(ppm)0 to 200.0%
Temp: -10 to 110
Accuracy:
Cond ±0.5% full scale
DO ±0.10 mg/L
Temp: ±0.4oC
ATC
Cond 0 to 50oC
DO 0 to 45oC
Other Parameters:
Storage Data: 600 groups; Communication ConnectorRS-232;
Power:DC9V/300mA.
Whats included:
2401-M glass conductivity electrode K=1,ATC
DO500 dissolved oxygen electrode
Model 602 flexible electrode holder
Model 901 intelligent stirrer
RS-232 communication software
Features and Applications:
Conductivity and dissolved oxygen double-parameter meter with high accuracy.
Inside setup with function of high purified water non-linearity automatic temperature compensation, suitable for accurate conductivity measurement for high purified water.
New type dissolved oxygen electrode has function of salinity measurement, can automatic achieve salinity compensation and temperature compensation; meter inside with air pressure sensor, can automatic achieve air pressure compensation;
Polarographic type dissolved oxygen electrode, short polarization time, fast response and accurate measurement.