TR-ON-B1 Microprocessor pH/mV Meter


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-ON-B1 Microprocessor pH/mV Meter
  • Model : TR-ON-B1
  • Erp code: 9000000722
  • | Share

TR-ON-B1.gif

Single Point Push-Button Calibration:
TR-ON-BW series with single point calibration function, you need only set conductivity value of the calibration solution at 25oC and immerse conductivity electrode into solution, then press ENTER key, the meter will calibrated automatically.


Auto Temperature Compensation:
TR-ON-B12DW will recognize the temperature sensor automatically and measure temperature after temperature sensor connected to the meter. If the conductivity electrode connected to it, the meter will enter automatic temperature compensation.

Adjustable Temperature Coefficient:
Different ion solution usually have different temperature coefficient, setting temperature coefficient correctly is very important to measurement, TR-ON-BW series can be set in the range of 0 to 3.9%per centigrade degree.


Adjustable Cell Constant:

When measuring higher or lower conductivity solution, you should choose conductivity electrode with different constant. The meter with three cell constant (0.1,1,10) for your choice.


What's included:

DJS-1 Conductivity electrode (K=1), Electrode holder, Power adapters, Temperature probe (Only for TR-ON-B12DW)


Auto-Ranging for Conductivity:
The meter with auto-ranging function when measure conductivity. After electrode immersed in solution, the meter will fast response and convert range.

   Model
TR-ON-B11AWTR-ON-B307WTR-ON-B12DW
    Conductivity Range
0~1.999, 19.99, 199.9, 1999uS/cm, 19.99, 199.9mS/cm
    Conductivity Accuracy
 ±1.5% F.S ±1% F.S±1% F.S
     Temperature Range
------0~100.0oC
    Temperature  Accuracy
------±1oC
    Calibration Points
1 Points

     Calibration Solution
146.6uS/cm, 1408uS/cm, 12.85mS/cm
     Temperature Compensation
0~50oC, Manual0~50oC, Manual0~50oC,   Automatic
    Temperature Coefficient
0~3.9%/oC

    Cell Constant
K=0.1, 1, 10, Adjustable

    Display
LCD

    Power Requirements
DC9V, using AC adapters, 220VAC, 50Hz
    Dimensions
210(L)mm×205(W)mm×65(H)mm
    Weight
1.5kg


Auto-Ranging for Conductivity:
The meter with auto-ranging function when measure conductivity. After electrode immersed in solution, the meter will fast response and convert range.

   Model
TR-ON-B11AWTR-ON-B307WTR-ON-B12DW
    Conductivity Range
0~1.999, 19.99, 199.9, 1999uS/cm, 19.99, 199.9mS/cm
    Conductivity Accuracy
 ±1.5% F.S ±1% F.S±1% F.S
     Temperature Range
------0~100.0oC
    Temperature  Accuracy
------±1oC
    Calibration Points
1 Points

     Calibration Solution
146.6uS/cm, 1408uS/cm, 12.85mS/cm
     Temperature Compensation
0~50oC, Manual0~50oC, Manual0~50oC,   Automatic
    Temperature Coefficient
0~3.9%/oC

    Cell Constant
K=0.1, 1, 10, Adjustable

    Display
LCD

    Power Requirements
DC9V, using AC adapters, 220VAC, 50Hz
    Dimensions
210(L)mm×205(W)mm×65(H)mm
    Weight
1.5kg


0