TR-MA-02 Microphotometer


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-MA-02 Microphotometer
  • Model : TR-MA-02
  • Erp code: 9000000629
  • | Share

TR-MA-02.jpg


Brief introduction:
Mainly used for density measurement of the spectrograms taken by various spectrographs, to identify the content of some elements and to finish the quantitative analysis work of spectrums. It can also be used for density and photosensitivity check of photographic films, as well as for aberration measurement with other optical devices.


Technical parameters:


                    Type

TR-MA-02

 

        Magnification of measurement system

20 times NA0.26

23 times NA0.30

26 times NA0.34

29 times NA0.38

Magnification of projection system

21 times

                              Lighting

12 volt, 50 watt incandescent bulb

 

Main slit

width adjustment range: 0-3mm

Indication: 0.01mm

Height adjustment range :0-20mm

Indication: 2mm

 

Working station

Longitudinal movement range :
0-90mm

Indication: 1mm

Lateral movement range :0-220mm

Horizontal micro-range :0-25mm

Micro Indication: 0.01mm

 

Selenium cell
 

Effective area: 25mm diameter

Sensitivity :400-500 microamps / lm

Working life: 500 hours

Galvanometer

Sensitivity: 2.5 * 10 ¯ 9 On / mm / m

Oscillation period: 1 sec

Instrument Weight

50kg

Size

1500 * 900 * 800mm

 

 

Instrument sets


 

Microphotometer (with a galvanometer in):  1 set

Lighting (12 volts, 50 watts): 4

Selenium cell: 1 set

Feet pads(including a relatively soft one): 3

Adjust wrench with a square hole: 1

Manual: 1


Technical parameters:


Type

TR-MA-02

 

Magnification of measurement system

20 times NA0.26

23 times NA0.30

26 times NA0.34

29 times NA0.38

Magnification of projection system

21 times

                       Lighting

12 volt, 50 watt incandescent bulb

 

Main slit

width adjustment range: 0-3mm

Indication: 0.01mm

Height adjustment range :0-20mm

Indication: 2mm

 

Working station

Longitudinal movement range :
0-90mm

Indication: 1mm

Lateral movement range :0-220mm

Horizontal micro-range :0-25mm

Micro Indication: 0.01mm

 

Selenium cell
 

Effective area: 25mm diameter

Sensitivity :400-500 microamps / lm

Working life: 500 hours

Galvanometer

Sensitivity: 2.5 * 10 ¯ 9 On / mm / m

Oscillation period: 1 sec

Instrument Weight

50kg

Size

1500 * 900 * 800mm

 

 

Instrument sets


 

Microphotometer (with a galvanometer in):  1 set

Lighting (12 volts, 50 watts): 4

Selenium cell: 1 set

Feet pads(including a relatively soft one): 3

Adjust wrench with a square hole: 1

Manual: 1