  • Name: TR-TC-8018D Gasoline Oxidation Stability Tester (Induction Period Method)
  • Model : TR-TC-8018D
  • Erp code: 8000000076
  • | Share

Summary:
    The instrument is designed and made as per national standard of People’s Republic of China GB/T8018-87 Gasoline - Determination of oxidation stability - Induction period method. It is suitable to determine the oxidation stability of gasoline. It can also be used to do determination as per ASTM D525 Standard Test Method for Oxidation Stability of Gasoline (Induction Period Method)
 
Main technical features:
1. Desktop structure. High precision and automation.
2. It uses USB port to communicate with PC. Easy to operate. 
3. Metal bath. No pollution. No need to adding water. 
4. Well designed heat preservation system. It can save energy as well as prevent operator from scalding. 
5. The bomb assembly is unit-body design. It shorts the pressure testing pipe and makes the pressure determination more accurate. It also guarantees the bomb being well sealed to make the test result more reliable.  
6. All parameters will be shown on PC during determination. The curves of pressure in these two bombs will also be drawn in real time. The test result is clear at a glance.

 

Main technical specifications:

  1. Power supply: AC220V±5%,50Hz

2. Heating power: 1600W, the actual heating power is automatically controlled by computer
3. Measuring range of oxygen bomb pressure transmitter:(0~1600)kPa, accuracy:±2
4. Temperature control point of metal bath: 100.0℃±1℃
5. Thermometer: Mercury-in glass thermometer, can correct coefficient as need.
6. Ambient temperature: ≤30℃
7. Relative humidity: ≤85%


SYD-8018D.jpg

Main technical specifications
1. Power supply: AC220V±5%,50Hz
2. Heating power: 1600W, the actual heating power is automatically controlled by computer
3. Measuring range of oxygen bomb pressure transmitter:(0~1600)kPa, accuracy:±2
4. Temperature control point of metal bath: 100.0℃±1℃
5. Thermometer: Mercury-in glass thermometer, can correct coefficient as need.
6. Ambient temperature: ≤30℃
7. Relative humidity: ≤85%


No.

Item

Unit

Qty

Remarks

1

Laptop

Set

1


2

Oxygen bomb test assembly

Set

2


3

USB interface cable

Piece

1


4

Glass mercury thermometers 95-103℃, sale division is 0.1 ℃

Piece

1

ID: GB-60

5

Fuse

Piece

2

15A

6

Joint oxygen cylinders and 6 mm PU tube, etc

Set

1


7

Stainless steel test hole cover

Piece

2


8

Glass test bottle and cover

Set

4


9

O type sealing ring for oxygen bomb

Set

2


10

Oxygen bomb special wrench

Piece

1


11

Thermometer frame

Piece

1



0