TR-TC-1900 Double Beam UV Spectrophotometer 190-1100nm


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TC-1900 Double Beam UV Spectrophotometer 190-1100nm
  • Model : TR-TC-1900
  • Erp code: 9000000168
  • | Share


19系列.Jpg

Instrument Function:

l   Photometric measurements: simultaneous measurements at a wavelength of 1~ 6 of transmittance and absorbance.

l   Spectral measurement: in the wavelength range for transmission, absorbance and energy spectrum scanning, and various data processing such as peak and valley detection, derivative computation, spectrogram operation, etc.

l   Quantitative measurement: single wavelength, dual wavelength, three wavelength and multi-wavelength measurement. 1 ~ 9 work curve (1 ~ 4 times) regression.

l   Dynamic measurement: time scanning of transmittance and absorbency in any set of wavelengths and may carry on various data operations.

l   Data output: can undertake data file and parameter file access; the measured results are output in standard data file format.

 

Main features:

l   The newly designed excellent optical system, high-performance holographic blazed grating, to ensure the instrument of low stray light.

l   Double beam metering system, with advanced circuit tt&c system, make the instrument with high stability and low noise.

l   Automatic control systems, advanced design concepts to ensure that instrument with high reliability and stability.

l   Removable structure of sample room design, easy to replace different attachments. To satisfy different analysis demand.

l   Capacious open source chamber design, make the light source change more convenient.

l   Key components are of high quality; guarantee the high reliability of the instrument performance.

l   English and Chinese operating software under Windows environment, with much patent technology, provides abundant unique analysis capabilities.

 

Technical Parameters:

Model

TR-TC-1900

Wavelength range:

190 nm-1100nm

Light source:

Imported tungsten lamp and Deuterium Lamp

Optical system:

double beam optical system, CT-type optical, 1200 l / mm holographic diffraction grating

Wavelength accuracy:

<= +/-0.1nm(656.1nm D2); 

<= +/-0.3nm(full wavelength range)

Wavelength repeatability:

<=0.1nm

Stray light:

<=0.03%T (220 nm NAL liquor; 340nm NaNO2)

Photometric range:

-3A~ 3A

Noise:

<= 0.0003 Abs/h

Baseline straightness:

<= +/-0.001A

Spectral bandwidth:

2nm

Drifting:

<= +/- 0.0004 Abs/h

Photometric accuracy:

+/- 0.3%T(0~100%T)

Photometric repeatability:

0.001Abs (0~0.5Abs)

Measure Mode:

transmittance, absorbency, energy, reflection

Scanning speed:

Fast, Medium, Slow

Wavelength and the setting mode

Setting freely

Keyboard:

Film digital buttons

Detector:

Imported silicon battery

Data output:

Printer or USB port

Power:

AC 220V/ 50Hz or AC110V/60Hz

Weight:

26kg

  


Technical Parameters:

Model

TR-TC-1900

Wavelength range:

190 nm-1100nm

Light source:

Imported tungsten lamp and Deuterium Lamp

Optical system:

double beam optical system, CT-type optical, 1200 l / mm holographic diffraction grating

Wavelength accuracy:

<= +/-0.1nm(656.1nm D2); 

<= +/-0.3nm(full wavelength range)

Wavelength repeatability:

<=0.1nm

Stray light:

<=0.03%T (220 nm NAL liquor; 340nm NaNO2)

Photometric range:

-3A~ 3A

Noise:

<= 0.0003 Abs/h

Baseline straightness:

<= +/-0.001A

Spectral bandwidth:

2nm

Drifting:

<= +/- 0.0004 Abs/h

Photometric accuracy:

+/- 0.3%T(0~100%T)

Photometric repeatability:

0.001Abs (0~0.5Abs)

Measure Mode:

transmittance, absorbency, energy, reflection

Scanning speed:

Fast, Medium, Slow

Wavelength and the setting mode

Setting freely

Keyboard:

Film digital buttons

Detector:

Imported silicon battery

Data output:

Printer or USB port

Power:

AC 220V/ 50Hz or AC110V/60Hz

Weight:

26kg

  