TR-TC-380B Sulfur Content Tester (Lamp method)


COMPANY : Tryte Technology (H.K.) Limited
ADD : UNIT 04, 7/F, BRIGHT WAY TOWER, NO. 33 MONG KOK ROAD, KOWLOON, HONGKONG.
TEL:00852-2389298
FAX: 00852-35902333
CELL:0086-15367067787(Robin)
SITE : www.trytetc.com
SKYPE : live:myformat666
EMAIL : sale@trytetc.com
more>>>

  • Name: TR-TC-380B Sulfur Content Tester (Lamp method)
  • Model : TR-TC-380B
  • Erp code: 8000000099
  • | Share

Summary:

    The instrument is designed and made as per the national standard of People's Republic of China GB/T380 Standard Test Method for Sulfur Content in Petroleum Products (Lamp Method). It is used to determine the sulfur content in light oils (such as gasoline, kerosene) which the Reid vapor pressure is not higher than 600mmHg as per GB/T380.
 
Main technical features:
1. Small desktop structure. Can do determination for 5 samples at a time.
2. The lamp is located in fixed seat. The height and sucking rate for each can be adjusted independently.
3. Stainless steel material. Reasonable design and easy to clean.
 
Main technical specifications:
1. Power supply: AC 220 V ±10%, 50 Hz
2. Sample quantity: Five independent groups.
3. Electromagnet pump: Five groups of main pumps, one group of auxiliary pump(stir pump).   
4. Vacuum pumping adjustment: It can be continuously adjusted by a potentiometer for each group.
5. Lamp adjustment: It can be adjusted up and down. The adjustment range is not less than 15 mm
6. Test tube holder: Each holder can be adjusted independently. Its adjustment range is not less than 20 mm.
7. Ambient temperature: -10 ℃~ 40 ℃
8. Relative temperature: ≤ 85%
9. Maximum power consumption:  150 W

10.Dimension: 380mm×320mm×600mm(including test vessels)



SYD-380B.jpg

Main technical specifications
1. Power supply: AC 220 V ±10%, 50 Hz
2. Sample quantity: Five independent groups.
3. Electromagnet pump: Five groups of main pumps, one group of auxiliary pump(stir pump).   
4. Vacuum pumping adjustment: It can be continuously adjusted by a potentiometer for each group.
5. Lamp adjustment: It can be adjusted up and down. The adjustment range is not less than 15 mm
6. Test tube holder: Each holder can be adjusted independently. Its adjustment range is not less than 20 mm.
7. Ambient temperature: -10 ℃~ 40 ℃
8. Relative temperature: ≤ 85%
9. Maximum power consumption:  150 W

10.Dimension: 380mm×320mm×600mm(including test vessels)


No.

Item

Unit

Qty

Remarks

1

Glass instrument for sulfur content test(glass absorber, droplet collector, flue, burning lamp)

Set

5


2

Stirring tube

Piece

1

Installed in the host computer

3

Glass bead

Bag

1


4

5A fuse (Ф5 × 20)

Piece

2


5

Gasket for lamp (lined in the rotation sheath of lamp to stop the lamp from moving)

Piece

5


6

Cotton yarn (wick)

Meter

0.5